![Sony SAL-1680Z Скачать руководство пользователя страница 96](http://html.mh-extra.com/html/sony/sal-1680z/sal-1680z_service-manual_394128096.webp)
4-50
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
*
DT 16-80mm F3.5-4.5 ZA)
4-12. WRITE dSB
Equipment
• Personal Computer
• Finished Inspection JIG (
AC 100 V
only)
• Lens Adjustment Program (ActuatorChecker)
1. Preparations
1)
Connected to equipment with checking lens. (Refer to Section 4-1-3.)
2)
Start up of “ActuatorChecker”.
3)
Click
[Set up]
, and perform the initial setting. (Refer to Section 4-1-4.)
2. Checking Method
1)
Click the
[Write dSB]
.
Fig.4-12-1
2)
The Serial window appears. Input the lens serial number.
Note:
When
[OK]
is clicked without inputting the serial number, the date executed is displayed on the completion window of each item.
Fig.4-12-2
3)
The “Select dsb” window appears.
4)
Being based on the image point shift amount calculated by “4-7. FOCUS-SHIFT CHECK/ADJUSTMENT (APERTURE (AMOUNT
OF SPHERICAL ABERRATION))”, select the button and perform the Write dSB.
Note:
• Writing dSB takes time for about 20 seconds.
• Do not remove the lens while writing it. The data of the lens becomes abnormal, and the exchange of substrates of main
flexible unit is needed.
Fig.4-12-3