background image

1-6

RM-PP1

Intermediate rail

Slide

Front

Ball retainer

17. Slide the unit in and out from the rack about three

times and check that the slide rails move smoothly.

If they are not smoothly, demount the unit and go back
to “Attaching the outer rails” (step 6).

c

When demounting the unit, carry it by the two persons

or more.

n

This unit does not have the feet at this operating.
Put down the unit on the floor or other, being careful

not to damage the unit.

18. Secure the unit to the rack with the four screws (RK5

20) and four ornamental washers.

Tightening torque: 120 

x

 10

 

_

2

 N

.

m {12.2 kgf

.

cm}

Rack

Ornamental
washers

Ornamental
washers

RK5 

x

 20

RK5 

x

 20

1-5. Rack Mounting

.

Mounting in rack

c

Be sure to carry the unit by the two persons or more.

13. Set each ball retainer to the position as shown in the

figure.

14. Pull both intermediate rails by equal length.
15. Slowly insert the inner rails into the intermediate rails.

16. Slowly push the unit into the rack while pressing each

stopper .

c

Be careful not to catch your finger or hand in rack

mount rail.

Intermediate rail

Stopper

Stopper

Inner rail

Содержание RM-PP1

Страница 1: ...PROGRAM PLAY BOX RM PP1 INSTALLATION MANUAL 1st Edition Serial No 10001 and Higher ...

Страница 2: ...sonne compétente uniquement Attention when the product is installed in Rack 1 Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack please make sure that the rack does not overload the supply circuit 2 Providing protective earth When this product is installed in a rack and is supplied power from an outlet on the r...

Страница 3: ...lation 1 1 Supplied Accessories 1 1 1 2 Operating Conditions 1 1 1 3 Power Supply 1 1 1 3 1 Voltage and Power Requirements 1 1 1 3 2 Recomended Power Cord 1 1 1 4 Installation Space 1 2 1 5 Rack Mounting 1 3 1 6 Connections and Setup 1 7 1 7 Matching Connectors and Cables 1 8 1 8 Signal Inputs and Outputs 1 9 ...

Страница 4: ...uals Besides this installation manual the following manuals are available for this unit Operation Manual PDF Supplied with this unit This manual is necessary for operation of this unit Operation Guide Supplied with this unit This guide has described how to use the Operation Manual PDF Maintenance Manual This manual describes the information that premises the parts level service for this unit Trade...

Страница 5: ...wer cord 125 V 10 A 2 4 m 1 557 377 11 2 Plug holder Brown 3 613 640 01 1 1 Supplied Accessories CD ROM 1 Program Play Box Control Software Operation manual PDF Operation guide 1 Installation manual 1 Screws for rack mounting B4 x 8 10 1 2 Operating Conditions c Good air circulation is essential to prevent internal heat build up Place the unit in location with sufficient air circulation Do not blo...

Страница 6: ...ion Space When installing the installation space must be secured in consideration of the ventilation and service operation Do not block ventilation slots at the right side panel and left side panel and vents of the fan Leave a space around the unit for ventilation Leave more than 20 centimeters of space in the rear of the unit to secure the operation area Dimensions when Rack Mounting n Remove the...

Страница 7: ...of the unit s operating temperature Refer to Section 1 2 Connect long enough cables on the connector panel considering that the unit is pulled out from the rack When the unit is mounted in a rack the maximum traveling distance is illustrated below 1 5 Rack Mounting Required Parts Use the specified parts for rack mounting The other supplied parts are not used Rack Mount Rail RMM 30 Option Slide rai...

Страница 8: ...PS3 x 14 PS3 x 14 Polyamide washers Polyamide washers Feet Feet Rack angle Rack angle Rack Mounting Procedure Attaching the rack angles and removing the feet 1 Attach the two rack angles to the unit using the four screws B4 x 10 and polyamide washers Tightening torque 120 x 10_2 N m 12 2 kgf cm c Pay the attension to the sharp edge of rack angle 2 Unscrew the four screws PS3 x 14 to remove the fee...

Страница 9: ...ws B5 x 8 1 5 Rack Mounting Rack Rack Unit mm 12 7 12 7 31 75 12 7 31 75 Rail Adjust Front bracket Rear bracket B5 x 8 B5 x 8 10 Check that the two intermediate rails attached to the rack are parallel 11 To fix the two outer rails to the rack fully tighten the eight loosely fitted screws B5 x 8 in step 9 12 Fully tighten the four rear bracket fixing screws which loosed in step 6 A A Intermediate r...

Страница 10: ... unit 18 Secure the unit to the rack with the four screws RK5 x 20 and four ornamental washers Tightening torque 120 x 10_2 N m 12 2 kgf cm Rack Ornamental washers Ornamental washers RK5 x 20 RK5 x 20 1 5 Rack Mounting Mounting in rack c Be sure to carry the unit by the two persons or more 13 Set each ball retainer to the position as shown in the figure 14 Pull both intermediate rails by equal len...

Страница 11: ...ay window of this unit refer to Error Messages of the operation manual Installation of Program Play Box Control Software When installing the Program Play Box Control Software in a computer please carry out according to the installer supplied with the software n Be sure to install this software in a personal computer with the following requirements When this software is installed in a personal comp...

Страница 12: ...2 SDI IN BNC 75Z MALE 1 1 569 370 12 SDI OUT TC OUT XLR 3P FEMALE 1 508 083 00 REMOTE IN RS 232C D SUB 9P FEMALE 1 563 815 21 RS 232C PLAYER REMOTE 9P remote control cable RCC G series _ RECORDER REMOTE or D SUB 9P MALE and 1 560 651 00 JUNCTION SHEEL 9P 1 561 749 00 1 Use the coaxial cable specified by the manual of the VTR that connects this unit Refer to the installation manual or the maintenan...

Страница 13: ...onnector RS 232C interface Remote control from a computer 7 RS 232C D SUB 9P connector RS 232C interface for example to perform selfdiagnostics Input connectors 1 SDI IN BNC x 1 Serial digital interface 270 M bps Complies with SMPTE 259M and ITU R BT 656 3 REF IN BNC x 2 in loop through connection Reference video signal Black burst or composite sync 0 3 V p p 75 Z sync negative Output connectors 2...

Страница 14: ... GND 2 RM TX _ 3 RM RX 4 GND 5 PRIORITY 6 GND 7 RM TX 8 RM RX _ 9 GND REMOTE IN RS 232C 9 pin male RS 232C 9 pin male Pin No Signal 1 DCD Data Carrier Detect Input 2 RXD Received Data Input 3 TXD Transmitted Data Output 4 DTR Data Terminal Ready Output 5 SG Signal Ground 6 DSR Data Set Ready Input 7 RTS Request to Send Output 8 CTS Clear to Send Input 9 NC ...

Страница 15: ...hat have a 20 V AC range are suitable See Fig A To Exposed Metal Parts on Set Fig A Using an AC voltmeter to check AC leakage AC voltmeter 5 25V Earth Ground 0 15 µF 1 5 kZ The material contained in this manual consists of information that is the property of Sony Corporation Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other ...

Страница 16: ...Printed in Japan Sony Corporation 2003 6 08 B P Company 2002 RM PP1 UC E 3 775 784 01 1 ...

Отзывы: