51
Troubleshooting
App
end
ix
1) The portion in lower case letters in the above codes is one of the following
numbers.
pp: Number identifying the corresponding port.
81: Port A
82: Port B
83: Port C
84: Port D
xx: Number identifying the error location. For details, refer to the Service
Manual.
zz: Number identifying the error type. For details, refer to the Service
Manual.
Warning Messages
When one of the problems described below is detected by
the unit, a warning mark appears on the status bar of the
web menu. Operation can continue even when the warning
mark appears. When multiple errors occur simultaneously,
the number of errors is indicated to the right of the warning
mark.
After a warning message appears, resolve the cause of the
warning based on the message.
For details on resolving the causes of warning messages,
refer to the Service Manual.
D4xx01
AV READ ERROR1, etc.
An error occurred while reading from memory. For details,
refer to the Service Manual.
D5xx01
SLOT Mx INTERFACE ERROR1, etc.
Cannot use memory because cannot communicate with the
memory inserted in the unit. If this error persists after
turning the unit on again, the unit or memory may be faulty.
D6xx01
SLOT Mx UNMOUNT ERROR1, etc.
An error occurred when attempting to unmount memory.
The memory may not be usable. If error D7xx01 occurs
every time the power is turned on, the data must be
salvaged.
D7xx01
SLOT Mx MOUNT ERROR1, etc.
An error occurred when detecting the memory.
If error D7xx01 occurs every time the power is turned on,
the data must be salvaged.
D80101
SLOT Mx FILE SYSTEM ERROR
An error was detected with the file system in memory.
If the same error occurs every time the power is turned on,
the memory must be formatted. Follow the on-screen
instructions to format memory.
E101pp
PORT x COND3 BAD, STOP REC
Recording was aborted because all the swap space to
replace bad memory cells has been consumed in the
memory in use.
E106pp
PORT x FS STUFFED, STOP REC
Recording was aborted because file system control limits
have been reached in the memory in use. Format the
memory to use it for recording.
E108pp
PORT x WRITE FAIL, STOP REC
Recording was aborted to protect existing data because an
attempt was made to overwrite data in the memory in use.
Format the memory to use it for recording.
E10901
SLOT Mx CANNOT REC
An abnormality was detected in an unrecorded area in
memory. This memory cannot be used for recording.
Format the memory to use it for recording.
E43100
INTERNAL MEMORY LACK
Some or all of the internal memory boards are not installed.
E43200
INTERNAL MEMORY WRONG POSITION
An internal memory board was inserted in the wrong
position.
Code
1)
Indication
Description
Code
1)
Indication
2)
Description
010100
NO EXTERNAL REFERENCE
(NO EXT REF)
No reference signal is input to the selected REF. INPUT
port. The unit is using the internal reference signal.
020100
LOST LOCK
Synchronization was lost during playback, recording, or
editing.
0601pp
PORT x SDI INPUT PHASE NG
(P-x PHASE)
The input signals to the SDI 1 to 4 connectors on the
indicated port are out of phase.
Содержание PWS-4500
Страница 1: ...MULTI PORT AV STORAGE UNIT PWS 4500 OPERATION MANUAL English 1st Edition Revised 5 ...
Страница 23: ...23 System Screen Chapter 4 Web Menu Remote tab Makes settings related to remote control ...
Страница 33: ...33 Port Screen Chapter 4 Web Menu For output ports ...
Страница 63: ...Sony Corporation PWS 4500 SYL 4 589 925 16 1 2015 ...