background image

¨ ¨ ¨

10

English

CONTROLS AND ADJUSTMENTS

F. Property

F-1. Status

F-2. Recall

E. Advance

a. Press "

4

" to select Moire or Degauss.

b. Press "+" to proceed.

c. Press "+" or "–" to preferred picture.

Press "

4

" to select Status, Recall or Language sub-

manual.

The status show the current input signal information

such as Resolution, Horizontal Frequency and Vertical

Frequency.

Confirm the Recall action by pressing the "+" or cancel

the action by pressing the "–".

Caution:

1. If moire reduction is overdone, picture quality,

i.e. focus and vertical line stability will both be

effected.

2. Proper adjustment is recommended for not

effecting picture perfermance.

Содержание PR705F

Страница 1: ...nded Use of the Monitor 7 CONTROLS AND ADJUSTMENTS 8 Front User Controls 8 General 9 Picture 9 Geometry 9 Color 9 Advance 10 Porperty 10 Signal 11 Contrast 11 Energy Declaration 11 TECHNICAL INFORMATION 12 Compatibility 12 Pin Assignment 12 Preset Timing Chart 13 TROUBLESHOOTING 14 DIMENSION 15 PLUG PLAY DISPLAY DATA CHANNEL DDC 16 MANUFACTURER S LIMITED WARRANTY 16 ...

Страница 2: ...his product be placed near or over a radiator or a heat register nor should the product be placed in a built in installation unless proper ventilation is provided 8 This product is equipped with a 3 wire grounding model plug This plug will only fit into a grounding model power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace y...

Страница 3: ...ever spill liquid of any kind on the product 11 Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltage points or other risks Refer all servicing to service personnel 12 Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions A When the power cord or plug is damaged or fraye...

Страница 4: ...s easy adjustment of image geometry and color settings for different display modes with the precision of a fixed frequency monitor The monitor also has full ergonomic features In addition to the friendly controls and user comfort features the emission level of the electric and magnetic field is kept low to meet the Swedish MPR II and TCO standards The monitor is also equipped with energy saving fu...

Страница 5: ...eeze and hold the latches 2 Pull the tilt swivel base to the rear of the monitor and lift to remove the base Installing the Tilt Swivel Base 1 Align the base with the slots on the bottom of the monitor and insert the tilt swivel base into the slots 2 Push the tilt swivel base firmly toward the front of the monitor until the latches click into the locked position INTRODUCTION Install Remove ...

Страница 6: ...ve Vertical Sync positive negative Composite Sync TTL Level positive negative Scan Frequency Horizontal 30 to 85 kHz automatically Vertical 50 to 160 Hz automatically Max Resolution 1600 x 1200 pixel non interlaced Display Colors Analog input unlimited colors Pixel Rate 175 5 MHz Plug Play DDC 1 DDC 2B Power Supply 100 120 VAC 200 240 VAC 50 60 Hz automatically Power Consumption 110W max Dimension...

Страница 7: ... where the overall background area just begins to disappear Allow adequate ventilation around the monitor so that the heat from the monitor can be properly dissipated Neither the monitor itself nor any other heavy objects should rest on the power cord Damage to the power cord can cause fire or an electric shock Keep the monitor away from high capacity transformers electrical motors or other strong...

Страница 8: ...onitor on or off 2 Power LED Indicator As long as the monitor is powered this indicator is lit In normal operation it lights green While in power saving mode the indicator will turn to amber 3 Adjust Keys To adjust the parameter of the selected function To adjust the contrast level of the screen 4 Menu Key To display and select the General Picture Geometry Color Advance Property Signal functions P...

Страница 9: ...d picture a Press 4 to select Side pin Balance Keystone Parallel and Rotate b Press or to preferred picture a Press 4 to select various white color temperature standards b In User item presss to confirm action color adjustment c Press 4 to select Red Green and Blue d Press or increase or decrease density 1 Press 3 or 4 to open the On Screen menu function Seven adjustment functions will appear on t...

Страница 10: ...Language sub manual The status show the current input signal information such as Resolution Horizontal Frequency and Vertical Frequency Confirm the Recall action by pressing the or cancel the action by pressing the Caution 1 If moire reduction is overdone picture quality i e focus and vertical line stability will both be effected 2 Proper adjustment is recommended for not effecting picture perferm...

Страница 11: ...e VESA Display Power Management Signaling DPMS standard This means that the monitor must be connected to a computer which also supports the VESA DPMS standard to fulfill the requirements of the NUTEK specification 803299 94 96 The time settings for switching to a power saving mode are adjusted from the system unit by software From the first indication of inactivity to power saving position A2 the ...

Страница 12: ...h detailed information on the pin assignment of the D Sub connector and the preset timing chart of the prevailing video standards Pin Assignment 5 10 15 11 6 1 Male Mini D 15 Connector TECHNICAL INFORMATION Signal 15 Pin Mini D Sub Red Video 1 Green Video 2 Blue Video 3 Horizontal Sync 13 Vertical Sync 14 Ground 4 5 6 7 8 10 11 No Connection 9 SDA DDC 12 SCL DDC 15 ...

Страница 13: ...75 985 67 500 68 677 80 468 79 976 H Sync Polarity Aµs Period 31 778 23 111 15 741 20 110 18 631 13 160 14 815 14 561 12 427 12 504 Bµs Pulse Width 3 813 1 556 1 749 1 117 1 138 1 074 1 185 1 016 1 073 1 067 Cµs Back Porch 1 907 2 222 1 731 3 910 2 702 1 951 2 370 2 201 1 945 1 837 Dµs Active Area 25 422 17 778 11 660 14 524 14 222 9 827 10 667 10 836 9 309 9 481 Eµs Front Porch 0 636 1 555 0 601 ...

Страница 14: ...he Contrast and Brightness Controls Push the degauss button once CAUTION A minimum interval of 20 minutes should exist before the degauss button is pressed a second time when not switching between modes Do not hold the button down continuously Picture bounces or a wave pattern is present in the picture Relocate electrical devices that may be causing electrical interference See the inside front cov...

Страница 15: ...English 81588 15 English DIMENSIONS unit mm ...

Страница 16: ...ar free parts labor warranty in the unlikely event of product defect caused by material or workmanship The product should be returned with original packaging proof of purchase or RMA Number Furthermore it is understood and agreed that the returned product is freightage prepaid and fully insured for one way transit by the Purchaser within valid warranty period The defective monitor will be repaired...

Отзывы: