3-37 (E)
HDC-P1
Adjustment Procedure
1. Set the format to “1080/59.94i”.
(For the format change procedure, refer to the Opera-
tion Manual.)
2. Set the TEST1 button of MSU-900 to ON (lighting) to
display the TEST SAW waveform and check that the
amplitude is 700 mV on the waveform monitor.
3. If the amplitude is not 700 mV, adjust the amplitude by
the following menu.
MENU:
SERVICE
PAGE:
WHITE
SHADING
ITEM: WHITE [R], [G], [B]
4. Execute STORE FILE.
MENU:
SERVICE
PAGE:
WHITE
SHADING
ITEM:
STORE
FILE
5. Set the TEST1 button of MSU-900 to OFF (light off).
6. Set the format to “720/59.94P”.
7. Make setting to the value adjusted in step 3 and ex-
ecute STORE FILE.
<WHITE SHADING> S11 TOP
[ R ] [ G ] [ B ]
V SAW : 00 00 00
V PARA : 00 00 00
H SAW : 00 00 00
H PARA : 00 00 00
WHITE : -3
m
-24 -14
STORE FILE: EXEC
COLOR_TEMP_SEL: 3200K
Содержание Power HADFX HDC-P1