2-2-6.
Error 71
When an internal storage error is detected, the following error code is displayed.
Main
code
Sub code
Mainte-
nance
logger
Drive log-
ger
Description
71
102
○
×
Number of the active drive is not enough. RAID cannot be configured.
2-2-7.
Error 91
When interface (between CPU and peripheral devices) errors are detected, the following error codes are displayed.
Tip
IT CPU: COM Express CPU Module/HPR-55 board
IO CPU: IC101/SY-438 board
FP CPU: IC1700/HPR-55 board
Main
code
Sub code
Mainte-
nance
logger
Drive log-
ger
Description
91
125
○
×
Communication between IT CPU and FP CPU is interrupted (detected
by IT CPU).
145
○
×
Communication between IT CPU and IO CPU is interrupted (detected
by IT CPU).
155
○
×
Communication between IT CPU and optical drive is interrupted (de-
tected by IT CPU).
215
○
×
Communication between FP CPU and IT CPU is interrupted (detected
by FP CPU).
415
○
×
Communication between IO CPU and IT CPU is interrupted (detected
by IO CPU).
430
○
×
IO CPU detected a flash memory (IC306, IC307/SY-438 board) error.
43A
○
×
IO CPU detected a serial number area error.
43C
○
×
IO CPU detected an adjustment data area (EEPROM IC1100/HPR-55
board, IC806/AU-366 board, IC502/VPR-118 board) error.
43D
○
×
IO CPU detected an hours meter area (FRAM: IC310/SY-438 board)
error.
557
○
○
A firmware alarm or startup of the recovery firmware was detected.
595
○
○
Communication between Disc Drive LSI (IC100: BD-42 board) and
BRIDGE (IC700: BD-42 board) cannot be established in optical block
assembly Ch-A during startup.
597
○
○
Failure in Disc Drive LSI (IC100: BD-42 board) firmware upgrade was
detected in optical block assembly Ch-A during startup.
5A5
○
○
Communication between Disc Drive LSI (IC200: BD-42 board) and
BRIDGE (IC700: BD-42 board) cannot be established in optical block
assembly Ch-B during startup.
5A7
○
○
Failure in Disc Drive LSI (IC200: BD-42 board) firmware upgrade was
detected in optical block assembly Ch-B during startup.
2-2-8.
Error 92
When synchronization system errors are detected, the following error codes are displayed.
PDW-HD1550
2-6
Содержание PDW-HD1550
Страница 1: ...PROFESSIONAL DISC RECORDER PDW HD1550 SERVICE MANUAL 1st Edition Revised 2 ...
Страница 12: ......
Страница 52: ...Hold the shaded portions Keep away a screwdriver Objective lens Actuator PDW HD1550 1 40 ...
Страница 54: ......
Страница 90: ......
Страница 102: ...Menu hierarchy M2 SERVICE SUPPORT M23 OPTION KEY STATUS INSTALL REMOVE PDW HD1550 4 12 ...
Страница 207: ...4 Install the removed parts by reversing the steps of removal PDW HD1550 6 47 ...
Страница 224: ......
Страница 252: ......
Страница 275: ......
Страница 276: ...PDW HD1550 SY PDW HD1550 CN E 9 878 590 03 Sony Corporation Printed in Japan 2018 8 08 2014 ...