5-1
PCV-R556DS/R558DS (UC)
Confidential
SECTION 5
SERVICE INFORMATION
5-1.
JUMPER SETTING ON HARD DISK DRIVE
The hard disk drive of service parts can be used without changing factory jumper setting, when it was replaced for service.
Model
Part No.
Maker
Code
Capacity
(formatted)
PCV-R556DS
1-772-712-11
Maxtor
93073U6
30 GB
PCV-R558DS
1-772-512-11
Maxtor
94098U8
40 GB
Master/Slave selection
Jumper setting
Factory setting
J42 Factory Reserved
J44 Factory Reserved
J46 4092 Cylinder Limitation
J48 Cable Select
J50 Master/Slave
Only drive in signal drive system
Master drive in dual drive system
Slave drive in dual drive system
Configuration Jumper Settings