6-19
Color bar chart picture frame
TV monitor picture frame
V
t = 0 msec
+ 0.1
– 0
A
B
A = B
C = D
D
C
6-2-12. Picture Frame Setting
Subject
Color bar chart standard picture frame
Measurement Point
VIDEO OUT terminal
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, t=0 msec
Setting method:
1) Turn the auto focus off.
2) Adjust the focus.
3) Adjust the zoom and the camera direction, and set to the speci-
fied position.
4) Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following adjust-
ments using “color bar chart standard picture frame”.
Check on the oscilloscope
1. Horizontal period
2. Vertical period
Fig. 6-8.
Check on the TV monitor
Fig. 6-9.
+ 0.1