Chapter 3
Connection and Operation
3-3
Chapter 3
3-2 Mixer Operation
3-2-1 Monitor Source Selection
The signals routed to the MONI OUT connectors are selected with the
switches of the MONITOR SOURCE section.
SEND monitoring
To monitor SEND signals, press the SEND switches one at a time, or press
SEND 1 and SEND 2 (or SEND 3 and SEND 4 ) simultaneously .
The SEND signal are passed to the MONI OUT 1 and MONI OUT 2
connectors as below.
When you press one SEND switch at a time
The selected SEND signal is routed to both the MONI OUT 1 and MONI
OUT 2 connectors.
When you press two SEND switches simultaneously
The selected odd numbered SEND signal (SEND 1 or SEND 3) is fed to
the MONI OUT 1 connector and the even numbered SEND signal (SEND
2 or SEND 4) is fed to MONI OUT 2 connector.
The SEND signals are monitored after the SEND MASTERS controls. So,
these signals reflect the output level.
Pre-fader listening (PFL) monitor
The PFL switch is an enable switch for pre-fader listening.
When this switch has been depressed, the PFL signal is routed to MONI
OUT 1 and MONI OUT 2 connectors, whenever you press the PFL switch
on an input channel.
LINE
1-2
EXT
1-2
RET
1-2
RET
3-4
SEND
1
SEND
2
SEND
3
SEND
4
MONITOR SOURCE
PFL
Select LINE OUT signals
Select EXT IN signals
Select RETURN signals
Select SEND signals
Select pre-fader monitoring
Содержание MXP-310
Страница 2: ...Table of contens 2 Table of contens ...
Страница 4: ...AAAAyA H L0 idx 1 2 Chapter 5 Function of parts and Controls H L0 footer ...
Страница 30: ...2 3 Output and Monitor Signal Section 2 26 Chapter 2 Locations and Functions of Parts and Controls Chaper 2 ...
Страница 34: ...3 4 Chapter 3 Connection and Operation Chaper 3 3 1 Mixer Connection ...