84
Pin No.
Pin Name
I/O
Description
1, 2
NC
O
Not used (open)
3
LEVEL L
O
L-ch level output to the CD mechanism controller (IC800)
4
LEVEL R
O
R-ch level output to the CD mechanism controller (IC800)
5 to 7
NC
O
Not used (open)
8
DAC MUTE
O
Muting control signal output to the D/A converter (IC300) “L”: muting
9
DARESET
O
Reset signal output to the D/A converter (IC300), A/D converter (IC301) “H”: reset
10
SLICER SEL
O
IEC958 input selection signal output to the D/A converter (IC300) “L”: MD, “H”: CD
11
LDLOW
O
Loading motor drive voltage control signal output for the loading motor driver (IC400)
“H” active
12
LDIN
O
Motor control signal output to the loading motor driver (IC400) “L” active *1
13
LDOUT
O
Motor control signal output to the loading motor driver (IC400) “L” active *1
Laser modulation select signal output to the HF module switch circuit
Stop: “L”, Playback power: “H”,
Recording power:
14
MOD
O
15
BYTE
I
External data bus line byte selection signal input “L”: 16 bit, “H”: 8 bit (fixed at “L”)
16
CNVSS
—
Ground terminal
17
XCIN
I
Sub system clock input terminal Not used (open)
18
XCOUT
O
Sub system clock output terminal Not used (open)
19
RESET
I
System reset signal input “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
20
XOUT
O
Main system clock output terminal (10 MHz)
21
VSS
—
Ground terminal
22
XIN
I
Main system clock input terminal (10 MHz)
23
VCC
—
Power supply terminal (+3.5V)
24
NMI
I
Non-maskable interrupt input terminal “L” active (fixed at “H” in this set)
25
DQSY
I
Digital In U-bit CD format subcode Q sync (SCOR) input from the CXD2662R (IC151)
“L” is input every 13.3 msec Almost all, “H” is input
26
PDOWN
I
Power down detection signal input terminal “L”: power down, normally: “H”
27
SQSY
I
Subcode Q sync (SCOR) input from the CXD2662R (IC151)
“L” is input every 13.3 msec Almost all, “H” is input
28
NC
O
Not used (open)
29
LDON
O
Laser diode on/off control signal output to the automatic power control circuit “H”: laser on
30
LIMIT-IN
I
Detection input from the sled limit-in detect switch (S101)
The optical pick-up is inner position when “L”
2 sec
0.5 sec
*1 Loading motor (M103) control
Mode
Terminal
LDIN (pin
qs
)
“L”
“H”
“L”
“H”
LDOUT (pin
qd
)
“H”
“L”
“L”
“H”
LOADING
EJECT
BRAKE
RUN IDLE
• MAIN BOARD IC801 M30805SGP (SYSTEM CONTROLLER (MD MECHANISM CONTROLLER)