2-2-2. Cleaning

1.   Front panel

The filter on the rear of the front panel can easily accumulate the dust. Be sure to remove dust by cleaning 
as follows.
(1)  Remove the front panel. (Refer to Section 1-4-1.)
(2)  Remove the dust accumulated on the filter with a vacuum cleaner.
 

n

 

Cleaning the filter by washing in water is recommended when there is a heavy accumulation of dust.

 

Be sure to dry the filter completely after it has been washed.

2. Fan

MVS-6520/6530/3000 is air-cooled by the fans (on both sides).
If dust has accumulated in the intake of the fan, air is prevented from flowing smoothly and this may 
result in a temperature rise inside the machine. This may have an adverse effect on performance and the 
life of the machine.
Cleaning of the fan every month is recommended.
Contact your local Sony Sales Office/Service Center for information on cleaning the fan.

Front panel

Filter

1

 Fan motor 120 square (for plug-in board)

2

 Fan motor (for power unit)

1

2

1

2

Air flow

Содержание MKS-6550

Страница 1: ...2M E MULTI FORMAT SWITCHER PROCESSOR MVS 6520 MVS 3000 3M E MULTI FORMAT SWITCHER PROCESSOR MVS 6530 FORMAT CONVERTER BOARD MKS 6550 DIGITAL MULTI EFFECT BOARD MKS 6570 INSTALLATION MANUAL 1st Edition ...

Страница 2: ...ifié pour en effectuer d autres Pour toute réparation faire appel à une personne compétente uniquement 安全のために 周辺機器を接続する際は 過大電圧を持 つ可能性があるコネクターを以下のポートに接続しない でください MVS コネクター UTIL SW コネクター UTIL SCU コネクター UTIL FM コネクター 上記のポートについては本書の指示に従ってください For safety do not connect the connector for periph eral device wiring that might have excessive volt age to the following ports MVS connector UTIL SW connector U...

Страница 3: ... 7 E 1 6 Matching Connectors and Cables 1 9 E 1 7 Input Output Signals of Connectors 1 10 E 1 8 Description of On board Switches LEDs and Connectors 1 12 E 1 8 1 MVS 6520 6530 3000 1 12 E 1 8 2 DVP 55 Board MKS 6570 1 22 E 1 8 3 FC 114 Board MKS 6550 1 24 E 1 9 System Connection 1 26 E 1 9 1 Connection Example of the MVS 6520 6530 System 1 26 E 1 9 2 Connection Example of the MVS 3000 System 1 27 ...

Страница 4: ... this unit User s Guide supplied with this unit This manual describes the information required for the actual application and op eration of this unit Startup Guide supplied with this unit This manual describes the information intended for the user who performs applica tion and operation of this unit for the first time Maintenance Manual Available on request This manual describes the maintenance an...

Страница 5: ...torage temperature _20 dC to 60 dC Mass when options are installed MVS 6520 Approx 20 kg MVS 6530 Approx 21 kg MVS 3000 Approx 19 kg Prohibited locations for installation Areas where the unit will be exposed do direct sunlight or any other strong lights Dusty areas Areas subject to vibration Areas with strong electric or magnetic fields Areas near heat sources Areas subject to electrical noise Are...

Страница 6: ...1 2 E MVS 6520 1 3 Installation Space External Dimensions MVS 6520 53 5 176 4U 18 2 6 5 485 7 375 440 482 60 5 380 Unit mm 134 Φ26 115 5 115 5 ...

Страница 7: ...1 3 E MVS 6520 MVS 6530 6 5 485 7 440 53 5 176 4U 18 2 375 482 60 5 380 134 Φ26 115 5 115 5 Unit mm ...

Страница 8: ...1 4 E MVS 6520 MVS 3000 440 375 53 5 176 4U 18 2 6 5 485 7 482 60 5 380 134 Φ26 115 5 115 5 Unit mm ...

Страница 9: ... is started with the POWER switch left on it may cause electrical shock or damage to printed circuit boards In MVS 6520 6530 3000 the slot for installing each plug in board is specified Install each board in the speci fied slot correctly according to the indications as described in 1 and 2 below 1 The board name is indicated close to the left of center of each plug in board 2 The board name is ind...

Страница 10: ...4 While the eject levers are opened as shown in the illustration insert the plug in board into the board guide rail MVS 6520 6530 option Name of option Plug in board Board name of the front side MKS 6570 DVP 55 board DVP MKS 6550 FC 114 board FC MVS 3000 option Name of option Plug in board Board name of the front side MKS 6550 FC 114 board FC Eject levers Plug in board Plug in board Eject lever Ej...

Страница 11: ...ath or serious injury Be sure to use the specified rack mount kit If not injury may result and the equipment may fall due to insufficient strength After rack mounting be sure to tighten the screws on the rack angle and fix the unit in the rack If the screws on the rack angle are not tightened the unit may slip from the rack and fall causing injury c When mounting the unit in the rack note the foll...

Страница 12: ...ail 4U 31 75 31 75 B4 x 10 B4 x 10 Unit mm 1U 5 Tighten the screws B4 x 6 two screws each on the right and left for adjusting the length of the adapter completely the screws that were loosened in step 3 6 Remove the front panel of the equipment Refer to Section 1 4 1 7 Align the groove of the rack bracket at the side of the equipment with the rail and slide the equipment to the rear n The rack bra...

Страница 13: ... sub 25 pin D sub 25 pin male TARRY GPI IN 7 12 OUT 17 32 Female Connector 25 pin male 1 560 904 11 1 TARRY GPI IN 1 8 OUT 1 16 Junction shell 25 pin 1 563 377 11 MVS RJ 45 modular _ _ UTIL SW 3 jack 2 UTIL SCU 3 UTIL FM 3 FM DEVICE USB 2 0 Type A _ _ receptacle 4 pin 1 The following crimp contact is required for the plug AWG 18 to 22 1 566 493 21 AWG 22 to 24 1 564 774 11 AWG 24 to 30 1 564 775 1...

Страница 14: ...UT 7 21 GPI OUT 9 22 GPI OUT 11 23 GPI OUT 13 24 GPI OUT 15 25 GPI OUT COM Ground for open collector output 1 Open collector output 1 13 14 25 External View External View 1 5 6 9 8 1 External View V GPI OUT 1 16 GPI OUT COM REMOTE S1 S2 RS 422A D sub 9 pin female DEVICE 2 from External Devices Pin No Signal Name Function 1 FG Frame ground 2 TX_ Transmitted data _ 3 RX Received data 4 GND Common gr...

Страница 15: ...round 2 RX_ Received data _ 3 TX_ Transmitted data _ 4 GND Common ground 5 _ No Connection 6 GND Common ground 7 RX_ Received data _ 8 TX_ Transmitted data _ 9 _ No Connection 4 TALLY INTERFACE UNIT BKDS 6080 and others REMOTE1 to 4 RS 422A D sub 9 pin female CONTROLLER to External Device Pin No Signal Name Function 1 FG Frame ground 2 RX_ Received data _ 3 TX Transmitted data 4 GND Common ground ...

Страница 16: ...dule 1 2 3 4 5 6 A C E F G H D16 D4 S2201 S501 M D408 D406 D404 D401 D502 D501 D1301 D1304 D1303 D1302 D2601 D410 D409 D407 D405 D403 D402 D412 D411 D3801 D3802 D3803 D3804 D1701 D4101 D4103 D4102 D1702 D1703 S1302 S3801 S3802 S502 S503 S601 D2 D5 D3 D1 D7 D8 D9 D17 D6 S2602 S2601 S3501 S3701 D3805 to D3820 D3702 D3703 D3704 D3705 D3701 D3903 D1601 D2001 S4101 S1301 D1305 to D1320 D1602 D1603 D160...

Страница 17: ...ut when the configuration of SWR CADEC FPGA is completed D1602 to D1605 K 1 SWR_CADEC LED0 1 to 3 Not used D2201 to D2203 M 1 SWR NIOS LED 1 to 3 SWR NIOS CPU status indication LED D201 C 2 12V 12V power status indication Lit when 12V is supplied If this LED is not lit the fuse may be blown D401 D 2 1 2V 1 1 2V 1 power status indication Lit when 1 2V is supplied D404 D 2 1 8V 1 1 8V 1 power status...

Страница 18: ...of the SBUS connection Used when connecting the external routing switcher to the SBUS terminal Factory setting Bit 2 is ON others are OFF D2601 C 1 SCU RESET SCU CPU reset status indication When S2601 is pressed When Reset is requested from software When IC4 does not start normally D1701 G 1 NO LOCK status LED REF IN status indication Lit when the format of signal that is input to the REF IN termi...

Страница 19: ...de setting of SCU NIOS IC5 Factory setting OFF all LED on CPU DP module D1 H 1 3 3V Power status indication Lit when 3 3V is supplied to the regulator on the CPU DP module normally D2 G 2 2 5V Power status indication Lit when 2 5V is supplied normally D3 H 1 1 8V_DDR Power status indication Lit when 1 8V is supplied to DDR2 on the CPU DP module normally D4 G 1 1 2V Power status indication Lit when...

Страница 20: ...6520 MIX 55 board MIX 55 board Side A A B C D E F G H J L N D302 D304 D305 D306 D303 D307 S600 D309 M 1 2 3 4 5 6 7 8 10 9 D308 D310 D700 D2200 2207 D2208 2215 D2300 2307 D2308 2315 D1000 D1004 CN1101 CN1100 D600 ...

Страница 21: ... Lit when 3 3V is supplied D305 D 1 2 5V 2 5V power status indication Lit when 2 5V is supplied D306 D 1 1 8V 1 8V power status indication Lit when 1 8V is supplied D303 D 1 1 2V 1 2V power status indication Lit when 1 2V is supplied D307 E 1 1 0V 1 0V power status indication Lit when 1 0V is supplied D309 E 1 0 9V 0 9V power status indication Lit when 0 9V is supplied D308 C 1 REG 1 5V A 1 1V A 1...

Страница 22: ... E MVS 6520 MY 119 board MY 119 board Side A CPU DP module A B C D E F G H J K L N D406 D402 D403 S601 S501 D1301 M D404 D401 D405 D1303 D1201 D705 D902 D702 D901 D701 D704 D703 D203 D1304 to D1319 7SEG LED ...

Страница 23: ...l is performed LED on CPU DP module Refer to LED on CPU DP module in 1 CA 85 board Switch on CPU DP module Refer to Switch on CPU DP module in 1 CA 85 board LED D203 C 1 12V 12V power status indication Lit in green when 12V is supplied D404 C 1 5V SSD 5V power for SSD status indication Lit in green when 5V is supplied D401 C 1 3 3V 3 3V power status indication Lit in green when 3 3V is supplied D4...

Страница 24: ...1 20 E MVS 6520 XPT 34 board XPT 34 board Side A A B C D E F G H M J K L P 1 2 3 4 5 6 7 8 D003 D202 D203 D204 D201 D205 D701 D401 9 D206 D702 D703 D704 D501 ...

Страница 25: ...pplied D204 C 1 1 8V 1 8V power status indication Lit when 1 8V is supplied D201 C 1 1 2V 1 2V power status indication Lit when 1 2V is supplied D205 C 1 0 9V 0 9V power status indication Lit when 0 9V is supplied D206 C 1 REG 1 2V CADEC 1 5V A1 to 4 1 1V A1 to 4 power status indication Lit when 1 2V CADEC 1 5V A1 to 4 and 1 1V A1 to 4 are supplied D701 D 1 MV1 Status indication of IC005 FPGA conf...

Страница 26: ...ard MKS 6570 n The number shown in the parentheses indicated the address on the circuit board DVP 55 board Side A A B C D E F G H I J K L M 1 2 3 4 5 6 7 8 D203 D302 D304 D305 D301 D306 D307 D601 D1102 9 D303 D1101 D909 D901 to D908 ...

Страница 27: ...on Lit when 2 5V is supplied D305 D 1 1 8V 1 8V power status indication Lit when 1 8V is supplied D301 D 1 1 2V 1 2V power status indication Lit when 1 2V is supplied D306 D 1 1 0V 1 0V power status indication Lit when 1 0V is supplied D307 D 1 0 9V 0 9V power status indication Lit when 0 9V is supplied D303 E 1 REG Status indication of 1 1V and 1 5V regulator Lit when the power is supplied from 1...

Страница 28: ...FC 114 Board MKS 6550 n The number shown in the parentheses indicated the address on the circuit board FC 114 board Side A A B C D E F G H I J K L M 1 2 3 4 5 6 7 8 D003 D202 D203 D204 D201 D206 9 10 D905 D904 D903 D902 D901 ...

Страница 29: ...tus indication Lit when the power is supplied to all DC regulators D905 E 1 CADEC FPGA configuration error indication When this LED is lit CPLD IC001 may not operate normally D904 E 1 FC12 FPGA configuration error indication When this LED is lit FPGA IC002 may not operate normally D903 E 1 FC34 FPGA configuration error indication When this LED is lit FPGA IC003 may not operate normally D902 E 1 FC...

Страница 30: ...inators Terminators are supplied in the product package b The figure shows the MVS 6530 c The figure shows the ICP 6530 IXS Series BKS R Series HDS X Series Cable with BNC connectors DVI cable USB cable MVS 6520 6530 Multi Format Switcher Processorb DCU 2000 C Device Control Unit Pack Reference video signal a ICP 6520 6530 Control Panel c ICP 6511 Menu Panel Reference video signal a MVE 8000A DME ...

Страница 31: ... 3000 Multi Format Switcher Reference video signal Camera Playback VTR CG video key signal generator etc Video output monitor program output preview multi viewer etc Recording VTR etc IN 1 to 32 OUT 1 to 16 AC power supplies ICP 3000 Control Panel AC power supplies Menu display monitor Removable disk ...

Страница 32: ......

Страница 33: ...0 Maintenance Manual Is the optional board inserted into the specified slot correctly Is the input output cable connected correctly Insert the optional board into the specified slot correctly Refer to Section 1 4 YES YES YES YES Is the software installed correctly The possible cause is the failure of MVS 6520 6530 3000 NO NO NO NO Perform the installation of software Refer to the User s Guide Chec...

Страница 34: ...re to dry the filter completely after it has been washed 2 Fan MVS 6520 6530 3000 is air cooled by the fans on both sides If dust has accumulated in the intake of the fan air is prevented from flowing smoothly and this may result in a temperature rise inside the machine This may have an adverse effect on performance and the life of the machine Cleaning of the fan every month is recommended Contact...

Страница 35: ...VS 6520 6530 3000 machine Leave the main power of the MVS 6520 6530 3000 turned on for two hours or longer in order to charge this capacitor The data is retained for about three days when the capacitor is fully charged under normal operating temperature and humidity However this period may vary depending on the storage environ ment Be sure to save necessary data in an external media ...

Страница 36: ......

Страница 37: ......

Страница 38: ...Sony Corporation MVS 6520 SY MVS 6530 SY MVS 3000 SY J E 4 446 372 01 Printed in Japan 2012 9 08 2012 ...

Отзывы: