151
Technical References
Phantom function (salvo function)
This function allows the switching of multiple crosspoints at the same time with a single button
operation. The following two types of settings can be made:
(1) “Local phantom”: Registers up to 64 crosspoints for each remote control panel.
(2) “Global phantom”: Registers up to 2,800 crosspoints for the routing switchers set by the
primary stations.
Names can be set for phantoms (groups of crosspoints switched simultaneously). Since
local phantoms are registered for each remote control panel, the same name can be used
for a different group of crosspoints on each remote control panel.
On the other hand, global phantoms are useful when there are many crosspoints to switch
simultaneously, or when sharing the same phantom across multiple remote control panels.
Also, the number of phantoms set for each unit can be increased by combining global
phantoms and local phantoms.
SET INHIBIT TABLE
DEST.
SOURCE
001
01--08
09--16
17--24
25--32
33--40
41--48
49--56
57--64
OUT001
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
--------
--------
--------
--------
OUT002
--------
--------
--------
--------
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT003
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT004
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT005
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT006
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT007
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT008
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
DEST.
SOURCE
009
01--08
09--16
17--24
25--32
33--40
41--48
49--56
57--64
OUT009
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT010
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT011
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT012
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT013
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT014
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT015
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
OUT016
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
xxxxxxxx
HDS-X5800 V1.00
F1: SEARCH
F2: JUMP
F3: LEFT
F4: RIGHT
STATION NUMBER 1
Ctrl-E: RETURN TO MENU
“-” mark is an inhibited crosspoint.
Figure-2
Crosspoint disabling function
Input/output system protection functions
(protect and secret functions)
There are two protection functions:
“Protect” function prevents the output destination from being re-assigned from another remote
control panel.
“Secret” function ‘hides’ the input sources that cannot be selected to any destination from any
remote control panel.
Crosspoint disabling function
This function inhibits individual crosspoints to limit the availability of each source to individual
destinations.
*SGC_0145-0161 02.3.19 5:37 PM Page 151
Содержание MK7807V1
Страница 1: ...Video and Audio Interfacing Guide Book 2002 2003 ...
Страница 12: ...10 SGC_001 0010 02 3 16 4 59 PM Page 10 ...
Страница 40: ...38 Routing Switchers Routing Switchers SGC_0011 0038 02 3 16 5 00 PM Page 38 ...
Страница 43: ...41 Common Accessories Common Accessories RMM 30 42 SGC_0041 0042 02 3 16 5 01 PM Page 41 ...
Страница 70: ...68 Interface Processor SP Series Interface Processor SP Series SGC_0043 0068 02 3 16 5 02 PM Page 68 ...
Страница 134: ...132 Interface Processor D Series Interface Processor D Series SGC_0117 0132 02 3 16 5 06 PM Page 132 ...
Страница 144: ...142 Interface Processor Others Interface Processor Others SGC_0133 0142 02 3 16 5 07 PM Page 142 ...
Страница 147: ...145 Technical References Routing Switchers 146 ISR 158 EDH 160 SGC_0145 0161 02 3 19 5 37 PM Page 145 ...