5-19
1. Power supply voltage check (FC-66 board)
Mode
Camera record
Subject
Any subject
Measuring Equipment
Digital voltmeter
PANEL 4.9 V check
Measuring Point
CN602 pin
5
Specification Value
4.9 ± 0.1 Vdc
PANEL 3.2 V check
Measuring Point
CN602 pin
7
Specification Value
3.20 ± 0.1 Vdc
PANEL 6.5 V check
Measuring Point
CN602 pin
9
Specification Value
6.5 ± 0.4 Vdc
PANEL 13.2 V check
Measuring Point
CN602 pin
6
Specification Value
13.2 ± 0.4 Vdc
PANEL –15.3 V check
Measuring Point
CN602 pin
8
Specification Value
–15.3 ± 0.4 Vdc
2. EVR initial data input
Mode
Playback
Signal
Any
Adjustment page
F
Adjustment address
30, 33 to 39, 3B
Adjustment procedure:
1)
Set data: 01 to page: 0, address: 01.
2)
Select page: F, and enter the data given in the following table.
Note:
Press the PAUSE button on the adjustment remote
commander each time the data are set, as the data are written
to nonvolatile memory (EEPROM).
Address
Data
Remarks
SHARP CASIO
30
BC
BB
BRIGHT adjustment
33
B9
77
White balance adjustment
34
B7
7A
White balance adjustment
35
BE
DB
CONTRAST adjustment
36
61
73
VCO adjustment
37
74
97
V-COM adjustment
38
C8
78
D RANGE adjustment
39
7C
36
V-COM level adjustment
3B
72
5E
Fixed value
Processing after adjustment finished:
1)
Set data: 00 to page: 0, address: 01.
3. VCO adjustment (PK-43 board)
Set the VCO free run frequency.
If disordered, LCD screen will be faulty.
Mode
Stop
Signal
None
Measurement point
PK-43 board CN802
7
pin (HSY)
Measuring equipment
Frequency counter
Adjustment page
F
Adjustment address
36
Specification value
15734 ± 30 Hz
Adjustment procedure:
1)
Set data: 01 to page: 0, address: 01.
2)
Set data: 20 to page: 3, address: 18, and press the PAUSE button
on the adjustment remote commander.
3)
Change the data on page: F, address: 36 so that the HSY signal
frequency satisfies the specification value.
4)
Press the PAUSE button on the adjustment remote commander.
Processing after adjustment finished:
1)
Set data: 00 to page: 3, address: 18, and press the PAUSE button
on the adjustment remote commander.
2)
Set data: 00 to page: 0, address: 01.
Содержание Mavica MVC-FD71
Страница 7: ...1 1 SECTION 1 GENERAL This section is extracted from instruction manual MVC FD71 ...
Страница 8: ...1 2 ...
Страница 9: ...1 3 ...
Страница 10: ...1 4 ...
Страница 11: ...1 5 ...
Страница 12: ...1 6 ...
Страница 13: ...1 7 ...
Страница 14: ...1 8 ...
Страница 15: ...1 9 1 9E ...
Страница 24: ...MVC FD71 4 1 4 2 4 3 4 1 FRAME SCHEMATIC DIAGRAM SECTION 4 PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS ...