5-16
9. Auto white balance adjustment
This adjustment corrects the output data of auto white balance. If
disordered, the colors will not be reproduced correctly in the auto
white balance mode.
Clear chart
Subject
(Shoot with color bar standard picture
frame)
Filter
Color temperature compensating filter
C14
Measurement point
Check DDS display on LCD screen
Measuring equipment
(Note 2)
Adjustment page
F
Adjustment address
D3, D4
Specification value
R ratio: 2B40 to 2BC0
B ratio: 5E40 to 5EC0
Note 1:
“Auto white balance reference data input” must be already
finished.
Note 2:
Right side 2 digits of data displayed at the lower right of
LCD screen.
00 00 XX
Displayed data
Adjustment procedure:
1)
Put the color temperature compensating filter C14 on the lens.
2)
Set data: 01 to page: 0, address: 01.
3)
Set data: 58 to page: 2, address: 10, and press the PAUSE button
on the adjustment remote commander.
4)
Turn off the HOLD switch on the adjustment remote
commander.
5)
After more than 2 seconds, turn on the the HOLD switch on
the adjustment remote commander.
6)
Set data: 0A to page: E, address: 11, and press the PAUSE
button on the adjustment remote commander.
7)
Set data: 3F to page: 2, address: 01, and press the PAUSE button
on the adjustment remote commander.
8)
Set data: 04 to page: 0, address: 03.
9)
Change the data on page: F, address: D3 so that average value
of DDS displayed data (Note 2) satisfies the R ratio specification
value.
10) Press the PAUSE button on the adjustment remote commander.
11) Set data: 05 to page: 0, address: 03.
12) Change the data on page: F, address: D4 so that average value
of DDS displayed data satisfies the B ratio specification value.
13) Press the PAUSE button on the adjustment remote commander.
Processing after adjustment finished:
1)
Set data: 00 to page: 2, address: 01, and press the PAUSE button
on the adjustment remote commander.
2)
Set data: 00 to page: 0, address: 03.
3)
Set data: 00 to page: 2, address: 10, and press the PAUSE button
on the adjustment remote commander.
4)
Set data: 15 to page: E, address: 11, and press the PAUSE button
on the adjustment remote commander.
5)
Set data: 00 to page: 0, address: 01.
10. White balance check
Clear chart
Subject
(Shoot with color bar standard picture
frame)
Filter
ND filter 1.0 and 0.3
Measurement point
Check DDS display on LCD screen
(Note 1, 2)
When data:0F is set to page: 2,
address: 01
(Note 1)
R-Y: 00 to 04 or FC to FF
Specification value
B-Y: 00 to 04 or FC to FF
When data: 00 is set to page: 0,
address: 00
(Note 2)
0E10 or more
Note 1:
Right side 4 digits of data displayed at the lower right of
LCD screen.
00 XX XX
R-Y
B-Y
Note 2:
Data displayed at the lower right of LCD screen.
00 XX XX
Displayed data
Adjustment procedure:
1)
Set data: 01 to page: 0, address: 01.
2)
Set data: 58 to page: 2, address: 10, and press the PAUSE button
on the adjustment remote commander.
3)
Turn off the HOLD switch on the adjustment remote
commander.
4)
After more than 2 seconds, turn on the the HOLD switch on
the adjustment remote commander.
5)
Set data: 15 to page: E, address: 11, and press the PAUSE button
on the adjustment remote commander.
6)
Set data: 02 to page: 0, address: 03.
7)
Set data: 56 to page: 2, address: 56, and press the PAUSE button
on the adjustment remote commander.
8)
Set data: 0F to page: 2, address: 01, and press the PAUSE button
on the adjustment remote commander.
9)
Confirm that the DDS displayed data (Note 1) is in a range of
“00 to 04” or “FC to FF”.
10) Set data: 00 to page: 0, address: 00.
11) Confirm that the DDS displayed data (Note 2) is more than
“E10”.
12) Put the ND filter 1.3 (1.0 + 0.3) on the lens.
13) Confirm that the DDS displayed data (Note 2) is lessthan “D0”.
Processing after adjustment finished:
1)
Set data: 00 to page: 2, address: 01, and press the PAUSE button
on the adjustment remote commander.
2)
Set data: 00 to page: 2, address: 56, and press the PAUSE button
on the adjustment remote commander.
3)
Set data: 00 to page: 2, address: 10, and press the PAUSE button
on the adjustment remote commander.
4)
Set data: 00 to page: 0, address: 01.
Содержание Mavica MVC-FD71
Страница 7: ...1 1 SECTION 1 GENERAL This section is extracted from instruction manual MVC FD71 ...
Страница 8: ...1 2 ...
Страница 9: ...1 3 ...
Страница 10: ...1 4 ...
Страница 11: ...1 5 ...
Страница 12: ...1 6 ...
Страница 13: ...1 7 ...
Страница 14: ...1 8 ...
Страница 15: ...1 9 1 9E ...
Страница 24: ...MVC FD71 4 1 4 2 4 3 4 1 FRAME SCHEMATIC DIAGRAM SECTION 4 PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS ...