— 27 —
KV-27FS12/27FS16/29FS12/29FS12C
horizontal center.
5. Press
then
to save into the memory.
H. Size Adjustment (HSIZ)
1. Input a monoscope signal.
2. Activate the Service Adjustment Mode.
3. Select HSIZ with
and
.
4. Adjust with
and
for the best horizontal size.
5. Press
then
to save into the memory.
V. Linearity (VLIN), V. Correction (VSCO),
Pin Amp (PAMP), and Horizontal Trapezoid
(TRAP) Adjustments
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select VLIN, VSCO, PAMP, and PPHA with with
and
.
4. Adjust with
and
for the best horizontal size.
5. Press
then
to save into the memory.
V LINEARITY (VLIN)
V CORRECTION (VSCO)
PIN AMP (PAMP)
HORIZONTAL TRAPEZOID (TRAP)
V. Angle (VANG), V. Bow (VBOW), Upper pin
(UPIN) and Low Pin (LPIN) Adjustments
1. Input a crosshatch signal.
2. Activate the Service Adjustment Mode.
3. Select VANG, VBOW, UPIN, and LPIN with
and
.
4. Adjust with
and
for the best picture.
5. Press
then
to save into the memory.
V ANGLE (VANG)
V BOW (VBOW)
UPPER PIN (UPIN)
LOW PIN (LPIN)
Service Adjustment Mode Memory
1. Change the value of the DCOL item to “1”.
2. After completing all adjustments, press
then
.
Read From Memory
SERVICE READ
Green
Red
ENTER
0
Содержание KV-27FS16 - 27" Trinitron Wega
Страница 28: ... 28 KV 27FS12 27FS16 29FS12 29FS12C NOTES ...
Страница 29: ... 29 KV 27FS12 27FS16 29FS12 29FS12C NOTES ...
Страница 30: ... 30 KV 27FS12 27FS16 29FS12 29FS12C NOTES ...
Страница 62: ...KV 27FS12 27FS16 29FS12 29FS12C NOTES 78 ...
Страница 63: ...NOTES KV 27FS12 27FS16 29FS12 29FS12C 79 ...