— 17 —
KV-27FS12/27FS16/29FS12/29FS12C
3-2. CONVERGENCE
Before starting convergence adjustments:
1. Perform FOCUS, V.LIN AND V.SIZE adjustments.
2. Set BRIGHTNESS control to minimum.
3. Feed in dot pattern.
Vertical Static Convergence
1. Adjust V.STAT magnet to converge red, green and blue
dots in the center of the screen (Vertical movement adjust
V.STAT RV 701 to converge).
B
G
R
Center dot
R G B
V.STAT magnet
RV701
V.STAT
2. Tilt the V.STAT magnet and adjust static convergence to open
or close the V.STAT magnet.
When the V.STAT magnet is moved in the direction of arrows
a and b, red, green, and blue dots move as shown below:
a
b
b
B
G
R
a
b
B
G
R
a
B
G
R
R
G
B
b
R
G
B
b
b
a
R
G
B
(1)
(3)
(2)
Dynamic Convergence Adjustment
Before performing this adjustment, perform Horizontal
and Vertical Static Convergence Adjustment.
1. Slightly loosen deflection yoke screw.
2. Remove deflection yoke spacers.
3. Move the deflection yoke for best convergence
as shown on the following page.
Horizontal Static Convergence
If the blue dot does not converge with the red and green dots,
perform the following:
1. Move BMC magnet (a) to correct insufficient H. Static
convergence.
2. Rotate BMC magnet (b) to correct insufficient V. Static
convergence.
3. After adjusting the BMC magnet, repeat Beam Landing
Adjustment.
BMC MAGNET
PURITY
V-STAT
b
BMC magnet
Содержание KV-27FS16 - 27" Trinitron Wega
Страница 28: ... 28 KV 27FS12 27FS16 29FS12 29FS12C NOTES ...
Страница 29: ... 29 KV 27FS12 27FS16 29FS12 29FS12C NOTES ...
Страница 30: ... 30 KV 27FS12 27FS16 29FS12 29FS12C NOTES ...
Страница 62: ...KV 27FS12 27FS16 29FS12 29FS12C NOTES 78 ...
Страница 63: ...NOTES KV 27FS12 27FS16 29FS12 29FS12C 79 ...