— 23 —
KV-[13M40/50/51], KV-[14MB40/40C/40A], KV-[20M40/S40/S41/V80], KV-[21SE40/40A/40C/80/80A/80C],
KV-[21MB40C/40M/40P], KV-[21ME40/40P], KV-[21SB40/40M/40P], KV-21XT4A
A
BOARD
R582 CONFIRMATION METHOD
(HV HOLD-
DOWN CONFIRMATION) AND READJUSTMENTS
The following adjustments should always be performed when
replacing the following components which are marked with
]
on
the schematic diagram:
IC301, IC521, IC602, D572, D573, D574, DY,
C507, C511, C574, C575, R578, R582, R583, R584,
R585, R586,R625, R626, R634, R635, T504 (FBT)
(1) Preparation before Confirmation
1) Turn the POWER switch ON. Input an entirely white
signal and set the PICTURE and BRIGHT controls to
maximum.
2) Confirm that the voltage between C574(+) and ground is
more than:
99.8VDC (for 20"/21")
95.0VDC (for 13"/14")
when the set is operating normally with 120.0
±
2.0 VAC,
(or 220.0
±
2.0 VAC supply for KV-14MB40C/40A,
21ME40C, 21MB40C, 21SE40C/40A/80C/80A, 21SB40C
and 21XT4A only).
(2) Hold-down Operation Confirmation
1) Connect the current meter between Pin 11 of the FBT
(T504) and the PCB land where Pin
11
would normally attach.
2) Input a dot signal and set PICTURE and BRIGHTNESS to
minimum:
IABL = 95+100/-95
µ
A (for 20"/21")
40+100/-40
µ
A (for 13"/14")
3) Confirm the voltage of A board TP-600 is
116.8
±
0.3VDC (for 20"/21")
117.0
±
0.3VDC (for 13"/14")
4) Connect the Digital Voltmeter and the DC power supply
via diode 1SS119 to C574 (+). (See figure 1.0 on next page.)
5) Increase the DC power voltage gradually until the picture blanks out.
6) Read the digital voltmeter indication.
7) Turn DC power source off immediately.
STANDARD
Less than or equal to:
127.3 VDC (for 20"/21")
117.75 VDC (for 13"/14")
8) Input a white signal and set PICTURE and BRIGHTNESS to Max
SECTION 4
SAFETY RELATED ADJUSTMENTS
The following adjustments should always be performed
when replacing the following components which are marked
with
]
on the schematic diagram:.
IC001, IC602, R030, R624, R626, R632,
R633, R635, R636, R637, R638, R639
1) Supply 130
±
2.0
0
VAC (or 220.0
±
2.0 VAC supply for KV-
14MB40C/40A, 21ME40C, 21MB40C, 21SE40C/40A/80C/
80A, 21SB40C and 21XT4A only) to the set with a variable
auto transformer.
2) Input a dot signal.
3) Set the PICTURE control and the BRIGHT control to
minimum condition.
4) Set to service adjustment mode.
5) Select PADJ with
and
.
6) Adjust with to the 0 level.
7) Confirm the voltage of A BOARD TP-600 is less than
125V DC.
8) If step 7 is not satisfied, replace the components, repeat the
above steps.
9) Supply 120.0
±
2.0 VAC (or 220.0
±
2.0 VAC supply for
KV-14MB40C/40A, 21ME40C, 21MB40C, 21SE40C/40A/
80C/80A, 21SB40C and 21XT4A only) to the set with a
variable auto transformer.
10) Adjust with
and
for:
116.8
±
0.3V DC (for 20"/21")
117.0
±
0.3V DC (for 13"/14")
11) Write into the memory by pressing
then
.
B+ VOLTAGE CONFIRMATION AND ADJUSTMENT
9)
Repeat steps from (4) to (7).
STANDARD
Less than or equal to:
127.3 VDC (for 20"/21")
117.75 VDC (for 13"/14")
(3) Hold-down Readjustment
If the current setting indicated in step 2-2 cannot be met,
readjustment should be performed by altering the resistance
value of R582, a component marked with
.
+
I ABL
ABL
T504
FBT
range
-
ammeter
3.0 mA DC
A