KE-32TS2U(UC)
2
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all
exposed metal parts to any exposed metal part having a return to chassis,
must not exceed 0.5 mA (500 microamperes).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA WT-
540A. Follow the manufacturers’ instructions to use these instruments.
2. A battery-operated AC milliammeter. The Data Precision 245 digital
multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a VOM or
battery-operated AC voltmeter. The “limit” indication is 0.75 V, so
analog meters must have an accurate low-voltage scale. The Simpson 250
and Sanwa SH-63Trd are examples of a passive VOMs that are suitable.
Nearly all battery operated digital multimeters that have a 2 V AC range
are suitable. (See Fig. A)
After correcting the original service problem, perform the following safety
checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-soldered
connections. Check the entire board surface for solder splashes and
bridges.
2. Check the interboard wiring to ensure that no wires are “pinched” or
contact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps, and
mounting hardware have been replaced. Be absolutely certain that you
have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly transistors, that
were installed during a previous repair. Point them out to the customer
and recommend their replacement.
5. Look for parts which, though functioning, show obvious signs of
deterioration. Point them out to the customer and recommend their
replacement.
6. Check the line cords for cracks and abrasion. Recommend the
replacement of any such line cord to the customer.
7. Check the connector shell, metal trim, “metallized” knobs, screws, and
all other exposed metal parts for AC Leakage. Check leakage as de-
scribed right.
Fig. A. Using an AC voltmeter to check AC leakage.
1.5 k
Ω
0.15
µ
F
AC
Voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
SAFETY CHECK-OUT
Содержание KE-32TS2U - 32" Flat Panel Color Tv
Страница 11: ...KE 32TS2U UC 1 7 1 7 TU BOARD REMOVAL 1 TU board ...
Страница 12: ...KE 32TS2U UC 1 8 1 8 H1 BOARD REMOVAL 2 Two screws BVTP 3x12 1 Screw BVTP 3x12 4 H1 board 3 H1 earth plate ...
Страница 14: ...KE 32TS2U UC 1 10 1 10 SWITCHING REGULATOR REMOVAL 2 Switching regurator 1 Eight screws PSW 3x6 ...
Страница 15: ...KE 32TS2U UC 1 11 1 11 PLASMA DISPLAY PANEL REMOVAL 1 Screw BVTP 4x16 1Screw BVTP 4x16 2 Plasma display panel ...
Страница 24: ...KE 32TS2U UC 3 5 3 2 CIRCUIT BOARDS LOCATION H2 B Q TU H1 UD ...
Страница 43: ...KE 32TS2U UC 3 24 COMPONENT SIDE CONDUCTOR SIDE UD UD BOARD ...
Страница 47: ...KE 32TS2U UC 4 2 4 1 COVER 2 2 1 7 6 5 4 1 3 2 2 1 1 1 1 1 1 1 1 1 4 4 4 9 9 8 1 1 8 3 3 3 6 ...
Страница 99: ...KE 32TS2U UC 99 Sony EMCS Corporation Ichinomiya TEC English 2002KL08 Data Made in Japan 2002 11 9 978 749 01 ...