KDL-22BX325/32BX325/32BX326/32BX425/40BX425
7
SELF DIAGNOSIS FUNCTIONS
VIEWING THE SELF CHECK DIAGNOSTIC LIST
For errors with symptoms such as “power sometimes shuts off” or “screen sometimes goes out” that cannot be confirmed, it is possible to
bring up past occurrences of a failure for confirmation on the Self Check diagnostic screen:
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY
Channel
5
Volume
-
POWER
.
* NOTE: This differs from accessing Service Adjustments Mode ()
Back
<<
002 MAIN_POWE
001
001 indicates an error was detected
003 AUD_PORT
000
000 indicates no error was detected
003 DC_ALERT
000
004 BALANCER
000
005 TCON_ERR
000
005 HFR_ERR
000
005 P_ID_ERR
000
005 PANEL_POWE
000
006 BACKLITE
000
007 TEMP_ERR
000
00000 00010 00000
[Menu] Exit
Panel Operation Time by Hour (max 99999)
Boot Count (max 99999)
Total Operation Time by Hour (max 99999)
SELF CHECK