8
Alarm
Protection
Panel Alarm
FPC Opened
Panel alarm line go through the edge
of the FPC.
Vs Protection
Panel Grid Opened
High Voltage Circuit Broken
Panel alarm line go through the edge
of panel.
This case is caused by sulfur issue.
Next parts will be broken, Scan
Board, Common Board, High Voltage
Board, Scan Relay Board.
CHECK POINT
FPC cutting at scan side and TCP
side.
CHECK POINT
Panel Grid condition.
CHECK POINT
Fuse on boards, Power HIC,
Between NEGA and POSI on scan
relay board
REWORK
Change the Scan, Common
board and Scan relay board.
REWORK
We can not rework this.
REWORK
We can not rework this.
No Picture