1-21(E)
JME-SA200
40
Adjustment
Registering and Recalling the Unit/Cell Numbers
5
Press the
v
or
V
button to select CONTRAST and press the
B
or
b
button to set the luminance level of the whole screen. Set to the
luminance level at which you can easily observe the display mode.
* S C R E E N U N I T / R E G I S T *
M O D E : W H I T E
C O N T R A S T :
1 5
U N I T N U M B E R C E L L N o .
X Y Z P X P Y
1 / 1 / 1 0 / 0
6
Assign the unit/cell number you want to register.
Press the
v
or
V
button to select X, Y or Z of UNIT NUMBER or PX
or PY of CELL No. and press the
B
or
b
button to change the number.
(Leave CELL No. PX: 0, PY: 0 to specify the whole unit.)
By pressing the
v
button, X, Y, Z, PX and PY are selected in order.
By pressing the
V
button, they are selected in the reverse order. The
specified unit flashes when WHITE or CUT OFF is selected, or the
frame of the specified unit lights when FRAME is selected.
The top-left unit or cell on the screen is counted as number 1 for either
horizontal (X) or vertical (Y) direction.
* S C R E E N U N I T / R E G I S T *
M O D E : W H I T E
C O N T R A S T : 1 5
U N I T N U M B E R C E L L N o .
X Y Z P X P Y
1
/ 1 / 1 0 / 0
7
Press the ENTER button.
The specified unit/cell number is stored in memory and “WRITE
COMPLETE!!” appears.
To register another unit/cell number
Repeat from the unit/cell number assignment (step
6
).
To register the unit/cell number in another mode
Press the MENU button once to return to the SCREEN UNIT CONTROL
display and repeat from the selection of REGIST (step
3
).
Notes
• Do not press the MENU button before pressing the ENTER button in step
6
. If you do, the specified unit/cell number is not stored in the memory.
• If the specified unit/cell number could not be stored correctly by pressing
the ENTER button in step
7
, “WRITE INCOMPLETE!!” appears. In this
case, try to store it again.
Luminance level
X:
Unit number in horizontal direction
Y:
Unit number in vertical direction
Z:
Screen number (Leave as 1 when only
one screen is installed.)
PX: Cell number in horizontal direction
PY: Cell number in vertical direction
Adjustment
41
Recalling the registered unit or cell
When you recall a registered unit or cell, the indicator on the rear panel of
the corresponding unit flashes.
1
Establish communication with the ICU controller (page 21) and
display the MAIN MENU.
2
Press the
v
or
V
button to select SCREEN UNIT CONTROL and press
the ENTER button.
The SCREEN UNIT CONTROL menu appears.
* S C R E E N U N I T C O N T R O L *
C H E C K
A D J U S T
R E G I S T
R E C A L L
3
Press the
v
or
V
button to select RECALL and press the ENTER
button.
The SCREEN UNIT/RECALL menu appears. The unit/cell number
stored first in the memory is displayed.
* S C R E E N U N I T / R E C A L L *
M O D E : S E L E C T
S E L E C T :
P R E V / N E X T
U N I T N U M B E R C E L L N o .
X Y Z P X P Y
1 / 1 / 1 0 / 0
D E L
D E L A L L
F 2
F 4
(continued)
LDU-15 JumboTron
display unit (rear)
Indicator
JTU-35 or JTU-17
JumboTron display unit (rear)
Indicator
Unit number
Cell number
Содержание JumboTron JME-SA200
Страница 1: ...SERVICE MANUAL MODEL DEST JME SA200 World SCREEN ALIGNMENT CONTROLLER ...
Страница 3: ......
Страница 36: ......
Страница 38: ......
Страница 40: ......
Страница 46: ......
Страница 48: ...8 2 8 2 JME SA200 SAK SAK A SIDE SUFFIX 11 SAK B SIDE SUFFIX 11 ...
Страница 50: ...8 4 8 4 JME SA200 SAP SAP SAP A SIDE SUFFIX 11 SAP B SIDE SUFFIX 11 ...
Страница 53: ...8 7 8 7 JME SA200 SAC SAC SAC B SIDE SUFFIX 11 ...
Страница 57: ......