![Sony Ipela SNC-CS50N Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/sony/ipela-snc-cs50n/ipela-snc-cs50n_user-manual_418026074.webp)
A
d
mini
s
tra
ting
t
he
Came
ra
Setting the Object Detection Function — Object detection Menu
74
Place an object in the window and confirm that
unattended object detection works correctly.
The object regarded as an unattended object is
marked with a green frame.
Note
It may take a long time until an unattended object is
detected, depending on the image being shot.
9
Click
OK
.
The unattended object detection settings are
confirmed.
Note
Be sure to click the
OK
button to confirm the
settings. The setting will be cancelled if you do not
click the
OK
button.
10
Set
Detection time
,
Alarm interval
and
Release
time
in the Unattended object setting tab.
Unattended object setting Tab
Use this tab to set the alarm time for unattended object
detection.
Time setting
Unattended object detection requires the following three
kinds of time settings.
Detection time
Set the period of time from when an object appears in an
active window and stops or when an object in an active
window disappears until the point when that object is
regarded as an unattended object. An alarm will be
output if the specified period has elapsed.
You can set the time between 40 seconds and 12 hours.
Alarm interval
You can repeat the alarm output in an interval of the
preset time after an object has been regarded as an
unattended object.
If you set
Alarm interval
to 5 minutes, for example, so
that an alarm will be output every 5 minutes repeatedly
after an unattended object is detected.
You can set the time between 1 and 6 hours.
Release time
Set the period of time required when the object once
regarded as an unattended object is regarded as a
background.
An alarm will no longer be output if the specified period
has elapsed as the object once regarded as an unattended
object is regarded as a background.
You can set the time between 1 and 12 hours.
Note
Set
Release time
to a larger value than
Detection time
.
OK/Cancel