6-121
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
3-3.
SERVO AND RF SYSTEM ADJUSTMENT
Before perform the servo and RF system adjustments, check that
the specified value of “Origin Oscillation Check” of “CAMERA
SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Adjusting Procedure:
1.
CAP FG duty adjustment
2.
Switching position adjustment
3.
Error rate check
1. Cap FG Duty Adjustment (VC-367 Board)
Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur.
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
16
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting a cassette.
2
0
01
01
Set the data.
3
3
01
1B
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes in
the following order.
“1B”
→
“2B”
→
“00”
5
3
03
Check that the data is “00”.
(Note2)
6
0
01
00
Set the data.
Note2:
If the data is “01”, adjustment has errors or the mechanism deck is
defective.
2. Switching Position Adjustment (VC-367 Board)
To obtain normal playback waveform output during the playback
mode, adjust the switching position.
Mode
VTR playback
Signal
SW/OL reference tape (XH2-3)
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Insert the SW/OL reference tape
and enter the VTR STOP mode.
2
0
01
01
Set the data.
3
C
10
EE
Set the data, and press PAUSE
button.
4
3
21
Check that the data is “02”.
(Note2)
5
3
01
0D
Set the data, and press PAUSE
button.
6
3
02
Check that the data changes to
“00”.
7
3
03
Check that the data is “00”.
(Note3)
8
0
01
00
Set the data.
Note2:
If the data of page: 3, address: 21 is “72”, the tape top being played.
After playing the tape for 1 to 2 seconds, stop it, perform step 5
and higher.
If the data of page: 3, address: 21 is “62”, the tape end being played.
After rewinding the tape, perform step 5 and higher.
Note3:
If bit 0 of the data is “1”, the EVEN channel is defective. If bit 1 is
“1”, the ODD channel is defective. Contents of the defect is written
into page: C, addresses: 10 and 12. See the following table. (For
the bit values, refer to “6-4. SERVICE MODE”, “4-3. 4. Bit value
discrimination”. ) If bit 3 of the data is “1”, the tape end being
played, so rewind the tape and perform the adjustment again.
When the EVEN channel is defective
When the ODD channel is defective
Data of page: C,
address: 12
EE
E8
E7
Contents of defect
Writing into EEPROM (IC8802) is defective
Adjustment data is out of range
No data is returned from IC4001
Data of page: C,
address: 10
EE
E8
E7
Contents of defect
Writing into EEPROM (IC8802) is defective
Adjustment data is out of range
No data is returned from IC4001
Содержание HVR-Z1C
Страница 2: ... 2 HVR Z1J Z1U Z1N Z1E Z1P Z1C SPECIFICATIONS ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 3: ... 3 HVR Z1J Z1U Z1N Z1E Z1P Z1C ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 478: ...Quick Reference Quick Reference 135 Z ZEBRA LEVEL 31 Zebra pattern 31 Zoom 22 ZOOM DISPLAY 80 Zoom ring 23 ...
Страница 479: ...Printed in Japan Printed on 100 recycled paper using VOC Volatile Organic Compound free vegetable oil based ink ...
Страница 481: ...ENGLISH JAPANESE ENGLISH JAPANESE ...