6-34
HVR-Z1J/Z1U/Z1N/Z1E/Z1P/Z1C
11. Flange Back Adjustment (PAL (50i) mode)
Copy the adjustment data of NTSC (60i) mode.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
60 to 70, F4
Specified Value
Data of page: F, address: 6F is “00” to
“0E”.
Note1:
This adjustment should be carried out upon completion of the
NTSC (60i) mode adjustments.
Note2:
This adjustment should be carried out upon completion of the
following adjustments of PAL (50i) mode.
“HALL Adjustment”, “MR Adjustment”
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
NTSC (60i)/PAL (50i) ............................................ PAL (50i)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
D0
0F
Set the data.
3
6
D1
60
Set the data.
4
6
D2
11
Set the data.
5
6
01
FB
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note5)
7
6
01
00
Set the data, and press PAUSE
button.
8
6
D0
0F
Set the data.
9
6
D1
F4
Set the data.
10
6
D2
01
Set the data.
11
6
01
FB
Set the data, and press PAUSE
button.
12
6
02
Check that the data changes to
“01”. (Note5)
5
F
6F
Check that the data is “00” to
“0E”.
Note5:
The adjustment data will be automatically input to page: F, address:
60 to 70, F4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
12. Flange Back Check (PAL (50i) mode)
Subject
Siemens star
(2.0m from the front of the lens)
(Luminance: 300
±
50 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE
end.
Note1:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
NTSC (60i)/PAL (50i) ............................................ PAL (50i)
2)
REC FORMAT (IN/OUT REC menu) .................. HDV1080i
(Page: 6, Address: 9B, Bit2=0)
3)
ND FILTER ...................................................................... OFF
(Page: 6, Address: 9B, Bit4=0, Bit5=0)
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Set the FOCUS switch to AUTO.
5)
Check that the lens is focused.
6)
Set the FOCUS switch to MANUAL.
9)
Change the zoom to the WIDE side from the TELE side, and
observe the TV monitor and check that the lens is focused.
Содержание HVR-Z1C
Страница 2: ... 2 HVR Z1J Z1U Z1N Z1E Z1P Z1C SPECIFICATIONS ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 3: ... 3 HVR Z1J Z1U Z1N Z1E Z1P Z1C ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 478: ...Quick Reference Quick Reference 135 Z ZEBRA LEVEL 31 Zebra pattern 31 Zoom 22 ZOOM DISPLAY 80 Zoom ring 23 ...
Страница 479: ...Printed in Japan Printed on 100 recycled paper using VOC Volatile Organic Compound free vegetable oil based ink ...
Страница 481: ...ENGLISH JAPANESE ENGLISH JAPANESE ...