6-60
HVR-V1J/V1U/V1N/V1E/V1P/V1C
34. Auto White Balance Check (ND 1)
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Clear chart (Color reproduction
adjustment frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 1
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080I
Checking method:
Order Page Address Data
Procedure
1
0
01
01
2
6
CA
05
3
6
C9
10
4
0
10
0A
5
E
8C
01
Press PAUSE (Write) button.
(AE)
6
0
10
00
OUTDOOR white balance check
7
6
01
4F
Press PAUSE (Write) button.
8
6
02
Check the data changes to
“01”.
9
6
0C
Check the data is “00”.
10
6
01
00
Press PAUSE (Write) button.
INDOOR white balance check
11
6
01
0F
Press PAUSE (Write) button.
12
6
02
Check the data changes to
“01”.
13
6
0C
Check the data is “00”.
14
6
01
00
Press PAUSE (Write) button.
InOut check
15
0
10
0A
16
E
8C
00
Press PAUSE (Write) button.
(AE)
17
0
10
00
18
Place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
19
6
C9
11
20
6
01
4B
Press PAUSE (Write) button.
21
6
02
Check the data changes to
“01”.
22
6
0C
Check the data is “00”.
23
6
01
00
Press PAUSE (Write) button.
24
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
CA
00
2
6
C9
00
3
0
01
00