6-36
HVR-V1J/V1U/V1N/V1E/V1P/V1C
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
64
04
3
0
10
0A
E
4
(AE)
8C
01
Press PAUSE (Write) button.
5
0
10
00
6
6
01
13
Press PAUSE (Write) button.
7
Wait for 2 seconds.
8
6
01
15
Press PAUSE (Write) button.
(Note 7)
9
6
02
Check the data changes to
“01”.
10
6
0C
Check the data is “00”.
11
0
10
06
12
F
2F
Check the data is “00” to
(6F)
“0E”.
13
0
10
00
Note 7:
The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F, 4C, 4D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to “01”.
4
6
01
00
Press PAUSE (Write) button.
5
6
64
00
6
0
10
0A
E
7
(AE)
8C
00
Press PAUSE (Write) button.
8
0
10
00
9
0
01
00
10
Perform “Flange Back
Adjustment (2)”.
7.
Flange Back Adjustment
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
7-1. Flange Back Adjustment (1)
RadarW
RadarW
RadarW
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
11, 20 to 3F, 4C, 4D
Specified value
Data of page: 6F, address: 2F is
“00” to “0E”
Data of pege: 6, address: 0C is “00”
Note 1:
Perform “HALL Adjustment”, “MR Adjustment” and
“Differential Gain Adjustment” before this adjustment.
Note 2:
Perform the adjustment with the lens in horizontal state.
Note 3:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5:
Don't touch the zoom lever during adjustment.
Note 6:
After adjustment, if the focusing to a subject located at
infinity failed, increase the illuminance of the chart and
perform readjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.