4-5 SYSTEM Setup Menu
EDIT
IN POINT
Set time data to cue up (Mark IN data). (The time data set is
displayed in the format “IN: xx:xx:xx:xx” in the time data field of
the display.)
TIMER REC
Sets the Timer Rec operating mode when the HKSR-102 is
installed.
For details on the settings, see 6-1 “Timer Rec” (page 74).
OFF [Off]: Do not use the Timer Rec function.
MANU [Manual]: Select manual Timer Rec.
AUTO [Auto]: Select auto Timer Rec.
Manu Frm
Selects the number of frames to record in 1 take when TIMER
REC is set to “MANU”.
1 to 10 Frame (1 Frame)
Auto Frm
Selects the number of frames to record in 1 take when TIMER
REC is set to “AUTO”.
1 to 10 Frame (1 Frame)
Interval
Specifies the recording interval (hours/minutes/seconds) when
TIMER REC is set to “AUTO”.
CACHE REC
Specified whether to use the Cache Rec function (only when the
HKSR-102 option board is installed).
For details on the settings, see 6-2 “Cache Rec” (page 76).
OFF [Off]: Do not use the Cache Rec function.
100% [100%]: Use the Cache Rec function.
RAMP
Specifies the Ramp operating function when SELECT FPS is set
to “ON” or “VTR”.
For details on the settings, see 7-2-3 “Using the Ramp Function”
(page 88) or 7-3-3 “Using the Ramp Function”.
OFF [Off]: Vary the number of frames shot (FPS) or the frame
frequency (FRM) manually with no range limits.
LINE [Auto(Linear)]: Vary the number of frames shot or the frame
frequency linearly.
INV [Auto(Inverse)]: Vary the inverse of the number of frames
shot (frm) or the inverse of the frame frequency (fps) linearly.
EVEN [Auto(Even)]: Vary the number of frames shot or the frame
frequency so that there area the same number of frames for
each frequency.
USER [Auto(User)]: Vary the number of frames shot or the frame
frequency along a user-specified curve.
MANU [Manual]: Vary the number of frames shot or the frame
frequency manually within preset upper and lower limits.
Auto Spd1
When RAMP is set to “LINE”, “INV”, or “EVEN”, sets the number
of frames shot/frame frequency of the ramp start point or the
number of frames shot/frame frequency of the ramp end point
(1FRM/FPS).
Auto Spd2
When RAMP is set to “LINE”, “INV”, or “EVEN”, sets the number
of frames shot/frame frequency of the ramp start point or the
number of frames shot/frame frequency of the ramp end point
(1FRM/FPS).
(This is the number of frames shot/frame frequency at the end
point when the number of frames shot/frame frequency of the
start point was set with Auto Spd1. Otherwise it is the number of
frames shot/frame frequency of the start point.)
Duration
When RAMP is set to “LINE”, “INV”, “EVEN”, or “USER”,
specifies the time (seconds) from the start of the ramp to its end.
0 to 30s (0s)
Load Curve
When RAMP is set to “USER”, displays a list of files saved to a
“Memory Stick”.
Item
Settings
Содержание HKSR-101
Страница 126: ...Index 126 Index ...