Status Display
BLK
γ
: Black gamma value
Flare
: Flare balance R/G/B value
DTL
: Detail level
The items along the bottom edge are common to both pages 1 and 2.
System status
The camera model name and signal format are displayed at
the top of the page (a “-” mark is displayed instead when a
camera is not connected).
Reference
: Reference signal format and lock status
SDI-1/2
: SDI OUTPUT 1/2 connector output format setting
SDI-3/4
: SDI OUTPUT 3/4 connector output format setting
Component
: Component signal connector output format
setting
Return1
: Return 1 return signal format setting
Return2
: Return 2 return signal format setting
Return3
: Return 3 return signal format setting
Return4
: Return 4 return signal format setting
CCU hardware diagnostics
The camera Auto Setup category, and the corresponding
setup item and status are displayed at the top of the page.
DPR
: DPR board status
DM
: DM board status
Front Panel
: HKCU-FP2 CCU control panel status (displayed
only when HKCU-FP2 is mounted)
Camera system diagnostics
Page 1 (HSCU300RF)
CAMERA:
Camera light sensor level
CCU:
CCU light sensor level
Fan Power:
CCU power supply fan status
Timer:
Elapsed time since power-on
CCU Power:
CCU power supply status
SerialNo
: CCU serial number
Page 1 (HSCU300R)
TRIAX Type
: Triax transmission mode
TRIAX Cable
: CCU triax cable connection status
TRIAX Comp.
: Triax cable compensation mode selection
TRIAX Step
: Triax cable compensation step (internal circuit
step display)
Fan Power:
CCU power supply fan status
Timer:
Elapsed time since power-on
CCU Power
: CCU power supply type and status
SerialNo
: CCU serial number
Page 2
CAMERA Cable
: Camera cable connection status
CAMERA Data
: Camera data transmission status
CAMERA Power
: Camera power supply status
CAMERA Tone
: Camera identification tone detection status
REMOTE Cable
: Remote device cable connection status
REMOTE Data
: Remote device data transmission status
REMOTE Power
: Remote device power supply status
Note
*System Status* 1/13
HSC300RF 1080/59.94I
Reference:Free Lock
SDI-1/2 :1080/59.94I
SDI-3/4 :525/59.94I
Component:SD YCD
Return1 :1080/59.94I
Return2 :525/59.94I
Return3 :NTSC
Return4 :NTSC
*Diagnosis* 2/13
DPR :OK
DM :OK
Front Panel :OK
*System Diag 1/3* 3/13
Optical Condition
CAMERA OK
CCU OK
Fan Power OK
Timer 56H
CCU Power AC OK
SerialNo 00002002
*System Diag 1/3* 3/13
TRIAX Type Digital
Cable Connect
Comp. Auto
Step 4
Fan Power OK
Timer 96H
CCU Power AC OK
SerialNo 100001
*System Diag 2/3* 4/13
CAMERA Cable Connect
Data OK
Power OK
Tone Detect
REMOTE Cable Connect
Data OK
Power OK