CONFIG 2 page of the MAINTENANCE menu
is set to RM)
• ASSIGN 1/3/4/5 switches and RET button on
the lens to which the electrical CC filter
function is assigned.
Paint adjustment when the remote
control unit is connected
The settings of the paint adjustment that were in
effect the last time the remote control unit was
used are recalled.
Function of the recording start/stop
buttons when the remote control unit is
connected
When the remote control unit is connected, you
can make a setting to determine which of the
recording start/stop buttons you will use. This
setting is made using the RM REC START item
on the CAM CONFIG 2 page of the
MAINTENANCE menu.
Relationship between the setting of the RM REC
START item and the function of recording start/
stop buttons
When the monitor is connected to the
MONITOR OUT connector of the remote
control unit
The MONITOR connector (BNC type) of the
RM-B150/B750 outputs the same signal as that
from the TEST OUT connector on the camcorder.
Use the black cable supplied with the RM-B150/
B750 to connect the monitor to the MONITOR
connector on the RM-B150/B750.
When the remote control unit is
disconnected from the camcorder
The camcorder settings return to the settings in
effect before the remote control unit was
connected.
Structure of the paint adjustment data
The non-volatile memory of the camcorder used
for storing paint adjustment data consists of two
regions as shown below: one is the “independent
data region” that is used when a remote control
unit is not connected, and the other is the “remote
control data region” that is used when a remote
control unit is connected. Paint adjustment data is
automatically selected and output to the camera
section depending on whether or not a remote
control unit such as the RM-B150 is connected.
Thus, when a remote control unit is connected to
the camcorder, the effective data region is
switched to the “remote control data region” and
the settings of the paint adjustment that were in
effect the last time the remote control unit was
used are recalled.
The settings of the absolute value rotational
controls
1)
and absolute value switches
2)
are
overwritten by those on the remote control unit
after the remote control unit is connected.
When the remote control unit is disconnected
from the camcorder, the “independent data
Recording start/
stop button
Settings of RM REC START
RM
CAM
PARA
Camcorder’s REC
START button
Disabled
Enabled Enabled
Lens’ VTR button Disabled
Enabled Enabled
Camcorder’s
ASSIGN 1/3/4/5
switches and lens’
RET button
assigned the
recording start/
stop function
Disabled
Enabled Enabled
Remote control
unit’s VTR button
Enabled
Disabled Enabled
RM-B150
MASTER BLACK
MASTER GAMMA
K
N
EE POI
N
T
DETAIL LE
V
EL
R/B GAI
N
R/B BLACK
MASTER BLACK
MASTER GAMMA
K
N
EE POI
N
T
DETAIL LE
V
EL
R/B GAI
N
R/B BLACK
Hardware of the
camera section
RM-B150 connected
RM-B150 not connected
Independent
data region
Remote control
data region
Setup menu of the
camcorder
Non-volatile memory