45
KMS
260B
20101
H0576
Iop = 57.6 mA in this case
Iop (mA) = Digital voltmeter reading (mV)/1 (
Ω
)
7. Then, move the multi-stick and display “LDPWR CHECK”
(C13).
8. Press the PUSH ENTER button once and display “LD 0.9 mW
$
”. Check that the reading of the laser power meter become
0.85 to 0.91 mW.
9. Press the PUSH ENTER button once more and display “LD
7.0 mW $
”. Check that the reading the laser power meter and
digital volt meter satisfy the specified value.
Note down the digital voltmeter reading value.
Specified Value :
Laser power meter reading : 7.0 ± 0.1 mW
Digital voltmeter reading : Optical pick-up displayed value ± 10%
(Optical pick-up label)
10. Press the CLEAR button while REC IT is lit and display
“LDPWR CHECK” (C13) and stop the laser emission.
(The CLEAR button is effective at all times to stop the laser
emission.)
11. Move the multi-stick to display “Iop Write”(C05).
12. Press the PUSH ENTER button. When the display becomes
Ref=@@@.@ (@ is an arbitrary number), press the PUSH
ENTER button to display “Measu=@@@.@” (@ is an arbi-
trary number).
13. The numbers which can be changed will blink. Input the Iop
value noted down at step 9.
To select the number : Move the multi-stick.
To select the digit : Press the MD REC MODE button while
REC IT is lit.
14. When the PUSH ENTER button is pressed, “Complete!” will
be displayed momentarily. The value will be recorded in the non-
volatile memory and the display will become “Iop Write” (C05).
Note 1: After step 4, each time the PUSH ENTER button is
pressed, the display will be switched between “LD 0.7 mW
$
”, “LD 6.2 mW $
”, and “LD Wp $
”. Nothing
needs to be performed here.
(For details of the method for checking
this value, refer to “6-8. Recording and
Displaying the Iop Information”.)
6-12. TRAVERSE ADJUSTMENT
Connection :
Adjusting Procedure :
1. Connect an oscilloscope to CN105 pin
4
(TE) and CN105 pin
6
(VC) of the BD board.
2. Load a test disc (MDW-74/GA-1). (Refer to Note 1.)
3. Press the
m
or
M
button while REC IT is off and move the
optical pick-up outside the pit.
4. Move the multi-stick and display “EF MO ADJUS” (C14).
5. Press the PUSH ENTER button and display “EFB =
MO-R”.
(Laser power READ power/Focus servo ON/tracking servo OFF/
spindle (S) servo ON)
6. Move the multi-stick so that the waveform of the oscilloscope
becomes the specified value.
(When the Multi sitck is moved, the
of “EFB=
” changes
and the waveform changes.) In this adjustment, waveform var-
ies at intervals of approx. 2%. Adjust the waveform so that the
specified value is satisfied as much as possible.
(Read power traverse adjustment)
(Traverse Waveform)
7. Press the PUSH ENTER button and save the result of adjust-
ment to the non-volatile memory (“EFB =
SAVE” will be
displayed for a moment. Then “EFB =
MO-W” will be dis-
played).
8. Move the multi-stick so that the waveform of the oscilloscope
becomes the specified value.
(When the Multi stick is moved, the
of “EFB-
MO-W”
changes and the waveform changes.) In this adjustment, wave-
form varies at intervals of approx. 2%. Adjust the waveform so
that the specified value is satisfied as much as possible.
(Write power traverse adjustment)
(Traverse Waveform)
9. Press the PUSH ENTER button, and save the adjustment re-
sults in the non-volatile memory. (“EFB =
SAVE” will be
displayed for a moment.)
10. “EFB =
MO-P”. will be displayed.
The optical pick-up moves to the pit area automatically and servo
is imposed.
V : 0.5 V/div
H : 10 ms/div
Input : DC mode
Oscilloscope
BD (MD) board
CN105 pin
4
(TE)
CN105 pin
6
(VC)
VC
A
B
Specification A = B
VC
A
B
Specification A = B
R
6-11. Iop NV SAVE
Write the reference values in the nonvolatile memory to perform
“Iop compare”. As this involves rewriting the reference values, do
not perform this procedure except when adjusting the laser power
during replacement of the optical pick-up and when replacing the
IC102. Otherwise the optical pick-up check may deteriorate.
Note: Perform this function with the optical pick-up set at room
temperature.
Procedure
1. Move the multi-stick to display “Iop NV Save” (C06).
2. Press the PUSH ENTER button and display “Iop [stop]”.
3. After the display changes to “Iop =xxsave?”, press the PUSH
ENTER button.
4. After “Complete!” is displayed momentarily, the display changes
to “Iop 7.0 mW”.
5. After the display changes to “Iop=yysave?”, press the PUSH
ENTER button.
6. When “Complete!” is displayed, it means that Iop NV saving
has been completed.
Содержание HCD-VZ50MD
Страница 8: ...8 BD CD board BD CD BOARD To repair the BD CD board remove the bottom plate Bottom view ...
Страница 57: ...HCD VZ50MD 57 57 7 4 SCHEMATIC DIAGRAM DECK SECTION E Page 64 TO MAIN BOARD 16 ...
Страница 59: ...HCD VZ50MD 59 59 7 6 SCHEMATIC DIAGRAM CD SECTION See page 50 for Waveforms See page 90 for IC Block Diagrams ...
Страница 64: ...HCD VZ50MD 64 64 7 11 SCHEMATIC DIAGRAM MAIN 1 4 SECTION ...
Страница 65: ...HCD VZ50MD 65 65 7 12 SCHEMATIC DIAGRAM MAIN 2 4 SECTION See page 89 for IC Block Diagrams ...
Страница 67: ...HCD VZ50MD 67 67 7 14 SCHEMATIC DIAGRAM MAIN 4 4 SECTION See page 89 for IC Block Diagrams ...
Страница 71: ...HCD VZ50MD 71 71 7 18 SCHEMATIC DIAGRAM DIGITAL 2 2 SECTION See page 92 for IC Block Diagrams ...
Страница 73: ...HCD VZ50MD 73 73 7 20 SCHEMATIC DIAGRAM AMP SECTION ...
Страница 77: ...HCD VZ50MD 77 77 7 24 SCHEMATIC DIAGRAM SWITCH SECTION ...
Страница 83: ...HCD VZ50MD 83 83 7 32 SCHEMATIC DIAGRAM POWER SUPPLY SECTION ...