![Sony HCD-PZ1D Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/sony/hcd-pz1d/hcd-pz1d_service-manual_416427030.webp)
HCD-PZ1D
30
DVD OFF LINE MODE
The system can be turned on under the situation not connected
with the CD mechanism deck.
Procedure:
• To enter DVD Off Line Mode
1. Press the [
\/1
] button to turn off the system.
2. Press the [REC TO USB] button, [DISC 3] button and [
\/1
]
button simultaneously.
3. The message “DVD OFF LINE MODE” appears on the LCD
module.
• To release from DVD Off Line Mode
1. To release from this mode, press the [
\/1
] button.
DVD SERVICE MODE
This mode let you make diagnosis and adjustment easily by using
the remote commander and the TV. The instructions, diagnostic
results, etc. are given on the on-screen display.
• TEST DISC LIST
Be sure to use the DVD disc that matches the signal standards
of your region.
• CD
YEDS-18 (Part No. 3-702-101-01)
PATD-012 (Part No. 4-225-203-01)
• DVD SL (Single Layer)
NTSC : HLX-503 (Part No. J-6090-069-A)
HLX-504 (Part No. J-6090-088-A)
PAL : HLX-506 (Part No. J-6090-077-A)
• DVD DL (Double Layer)
NTSC : HLX-501 (Part No. J-6090-071-A)
HLX-505 (Part No. J-6090-089-A)
PAL : HLX-507 (Part No. J-6090-078-A)
• Procedure to enter to DVD Service Mode:
1. Press the [
?/1
] button to turn on the system.
2. Press the [DVD] button.
3. Press the [
x
] button and [OPEN/CLOSE
Z
] button simultane-
ously and then turn the [MASTER VOLUME] dial clockwise.
4. The message “SERVICE IN” appears on the LCD module and
the Top Menu of Remocon Diagnosis Menu appears on the on-
screen display on the TV. The model name, main unit’s micom
version information (IF-con) and DVD
fi
rmware version infor-
mation (Syscon) are displayed at the bottom of the on-screen
display.
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
Model Name
IF-con
Syscon
: CMP_LA
: Ver. 00.06 (0000)
: Ver. 0.204
5. To execute each function, press its number by using numeric
button on the remote commander.
6. To release from this mode, press the [
?/1
] button to turn off
the system.
• Execute IOP Measurement
In order to execute IOP measurement, the following standard
procedures must be followed.
1. From the Top Menu of Remocon Diagnosis Menu, select “2.
Drive Manual Operation” by pressing the [2] button on the
remote commander. The following screen appears on the on-
screen display.
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Mecha test mode
5. MIRR time Adjust
0. Return to Top Menu
2. Select “3. Manual Adjustment” by pressing the [3] button on
the remote commander. The following screen appears on the
on-screen display.
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o
Change Value
RETURN Return to previous menu
3. Select “6. Iop:” by pressing the [6] button on the remote com-
mander.
4. Wait until a hexadecimal number appears in the on-screen dis-
play as below:
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eg Boost Adjust:
6. Iop. 48
7. TRV. Level:
8. S curve (FE) Level:
9. RFL (PI) Level:
0. MIRR Time:
O
o
Change Value
RETURN Return to previous menu
5. Convert data from hexadecimal to decimal by using conver-
sion table.
6. Please
fi
nd the label on the rear of the BU (Base Unit).
The default IOP value is written in the label.
7. Subtract between these two values.
8. If the remainder is smaller than 93 (decimal), then it is OK.
However if the value is higher than 93, then the BU is defec-
tive and need to be change.
9. Press the [RETURN] button on the remote commander to re-
turn to previous menu.
10. Press the [0] button on the remote commander to return to the
Top Menu of Remocon Diagnosis Menu.