5-16
4. Flange Back Check
Subject
Siemens star
(2.0 m from the front of the protection
glass)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at TELE end and WIDE end.
5. Picture Frame Setting
Setting method:
1) Adjust the zoom and the camera direction, and set to the specified
position.
2) Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color bar chart standard picture frame”.
1. Horizontal period
Subject
Color bar chart standard picture frame
(1.5m from the front of the protection
glass)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, t=0
±
0.1msec
2. Vertical period
Fig. 5-1-7.
Fig. 5-1-8.
A
A=B
B
C=D
C
D
t=0
±
0.1mesc
v
Color bar chart picture frame
TV monitor picture frame
Checking method:
1) Place the Siemens star 2.0m from the front of the protection
glass.
2) To open the IRIS, decrease the luminous intensity to the Siemens
star up to a point before noise appear on the image.
3) Select page: 2, address: 40, and set data: 02.
4) Select page: 2, address: 41, and set data: 01.
5) Shoot the Siemens star with the zoom TELE end.
6) Turn on the auto focus.
7) Check that the lens is focused (Note1).
8) Select page: 2, address: 21, and set data: 10.
9) Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Note 1:
When the auto focus is ON, the lens can be checked if it is
focused or not by observing the data on the page 1 of the
adjusting remote commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
n
Odd: Focused
Even: Unfocused
Processing after Completing Adjustments
1) Select page: 2, address: 21, and set data: 00.
2) Select page: 0, address: 03, and set data: 00.
3) Select page: 2, address: 40, and set data: 00.
4) Select page: 2, address: 41, and set data: 00.
Содержание Handycam Vision CCD-TRV300E
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ......
Страница 19: ......
Страница 20: ......
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 47: ...CCD TRV300E SECTION 3 BLOCK DIAGRAMS 3 1 OVERALL BLOCK DIAGRAM 3 1 3 2 3 3 3 4 ...
Страница 54: ...CCD TRV300E 3 26 3 27 3 28 3 8 B W EVF BLOCK DIAGRAM CCD TRV300E H 1Vp p IC901 11 H 2 2Vp p IC901 13 ...
Страница 55: ...CCD TRV300E 3 29 3 30 3 31 3 32E 3 9 POWER BLOCK DIAGRAM ...
Страница 57: ...CCD TRV300E 4 4 4 5 4 6 FRAME SCHEMATIC DIAGRAM 2 FRAME 2 ...
Страница 67: ...CCD TRV300E For schematic diagrams Refer to page 4 11 for Printed Wiring Board SERVO VC 195 7 9 4 39 4 38 4 40 ...
Страница 72: ...CCD TRV300E 4 57 4 58 4 59 STEREO MIC MA 332 ...
Страница 73: ...CCD TRV300E 4 60 4 61 4 62 PS 8990 CF 54 CONTROL SWITCH BLOCK PANEL SWITCH ...