1-3
ENGLISH
ENGLISH
HDR-SR1/SR1E_L2
1-3-3. Self-diagnosis Code Table
C
C
C
C
E
E
E
E
E
E
E
E
Block
Function
0
4
1
3
1
3
3
2
2
0
3
1
6
1
6
1
6
2
6
2
9
1
9
4
Detailed
Code
0
0
0
1
0
2
6
0
0
0
0
0
1
0
1
1
0
0
0
1
0
1
0
0
Symptom/State
Non-standard battery is used.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
Disk access error
Difficult to adjust focus
(Cannot initialize focus)
EEPROM data are rewritten.
Drive fault
Zoom operations fault
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality when flash is being charged.
Fault of writing to or erasing the
flashmemory
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Remove the power source. Reconnect it again and operate your
camcorder again.
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin
ql
,
wa
of
CN5201 on the LD-226 board). If it is OK, check the focus
motor drive IC (IC5204 on the LD-226 board).
Make EEPROM data correct value.
Inspect or replacement of the hard disk drive.
Inspect the lens block zoom MR sensor (pin
qh
,
qk
of CN5201
on the LD-226 board) when zooming is performed when the
zoom lever is operated, and the zoom motor drive circuit
(IC5204 on the LD-226 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect PITCH angular velocity sensors (SE6801 on the CM-074
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE6802 on the CM-074
board) peripheral circuits.
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC1601 on the VC-456 board).