1-4
HDR-HC3/HC3E/HC3K/HC3EK_L2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
E
E
E
E
E
Block
Function
6
1
6
1
6
2
6
2
9
1
Detailed
Code
1
0
1
1
0
0
0
1
0
1
Symptom/State
Zoom operations fault
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality when flash is being charged.
Self-diagnosis Code
Repaired b
y:
Correction
Inspect the zoom MR sensor of lens block (Pin
qh
,
qk
of CN7103
on the LD-202 board) when zooming is performed when the zoom
switch is operated and the zoom motor drive circuit (IC7204 on
the LD-202 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect pitch angular velocity sensor (SE7702 on the CM-071
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE7701 on the CM-071
board) peripheral circuits.
Checking of flash unit or replacement of flash unit. (Note)
1-6. PROCESS AFTER FIXING FLASH ERROR
When “FLASH error” (Self-diagnosis Code E:91:**) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is
changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the
following process.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data changes to “01”.
Note:
After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.