5-32
10. PAL Hi8 REC C Current Adjustment
(VC-197 board)
Set the recording levels of the REC AFM signal and REC ATF signal.
If the level is too low, the audio S/N will deteriorate, tracking will
not be stable, or SP/LP will not be discriminated properly. If too
high, color beets will be produced on the self-recording /playback
image.
Adjust the REC chroma signal recording current.
Mode
VTR recording
Signal
No signal
Measurement point
Pin
2
of CN207 (REC RF)
Measuring instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment page
F
Adjustment address
68 to 71
Specified value
A = 35.7 ± 1.3 mVp-p (ME, E, SP mode)
Adjusting method:
1)
Set page: 0, address: 01, data: 01.
2)
Insert a tape, and set to recording mode.
3)
Note down the data of page: F, address: 29, set data: 01, and
press the PAUSE button of the adjusting remote commander.
4)
Note down the data of page: D, address: 10, set data: 06, and
press the PAUSE button of the adjusting remote commander.
5)
Set page: 2, address: 61, data: 30 and press the PAUSE button
of the adjusting remote commander.
6)
Set page: 3, address: 01, data: 41 and press the PAUSE button
of the adjusting remote commander. (ME, E, SP mode)
7)
Change the data of page: F, address: 69, and set the REC C
signal level (A) to the specified value.
8)
Press the PAUSE button of the adjusting remote commander.
9)
Read the page: F, address: 69, data (D
69
).
10) Convert D
69
to a decimal number, to obtain D
69
´.
(Refer to Table 5-1-7. Hexadecimal notation-decimal notation
calculation table.)
11) Calculate the adjustment data (decimal) from the following
equations (decimal calculation), convert it to a hexadecimal
number, and input each adjustment address.
Address: 68
D
68
´ = D
69
´
Address: 6A
D
6A
´ = D
69
´
Address: 6B
D
6B
´ = D
69
´
Address: 6C
D
6C
´ = D
69
´ + 14
Address: 6D
D
6D
´ = D
69
´ + 14
Address: 6E
D
6E
´ = D
69
´ + 14
Address: 6F
D
6F
´ = D
69
´ + 14
Note :
After setting each data, be sure to press the PAUSE
button of the adjusting remote commander.
12) After setting data noted down at step 3) for page: F, address:
29, press the PAUSE button of the adjusting remote commander.
13) After setting data noted down at step 4) for page: D, address:
10, press the PAUSE button of the adjusting remote commander.
14) Set page: 3, address: 01, data: 00 and press the PAUSE button
of the adjusting remote commander.
15) Set page: 3, address: 01, data: 00 page: 3, address: 01, and
press the PAUSE button of the adjusting remote commander.
16) Set page: 0, address: 01, data: 00.
Note :
Do not insert a plug into the AUDIO (R) terminal.
Connection:
1)
Remove C1060 (0.01
µ
F, near Pin
5
of IC101).
Note :
After completing “REC L Level Adjustment” and
“REC C Current Adjustment”, replace C1060 with new
parts (1-162-970-11 CERAMIC CHIP 0.01
µ
F 10%
25V).
2)
Connect Pin
^£
of IC101 and GND with a 0.01
µ
F capacitor.
0.01
µ
F capacitor: 1-101-004-00
Fig. 5-3-17.
A
0.67
µ
sec
Center of the luminace line width
Center of the luminace line width
Содержание GV-A500E
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......