5-26
3. NTSC LP mode Switching Position Adjustment
(VC-197 board)
If deviated in this case causes switching noise or jitter on the LP
mode played back screen.
Mode
Playback
Signal
Alignment tape:
For tracking adjustment (WR5-1NP)
Measurement Point
CH1: Pin
3
of CN207 (RF SWP)
CH2: Pin
6
of CN207 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
38, 39
Specified Value
t1 = 0 ± 10
µ
sec
Adjusting method:
1)
Set page: 0, address: 01, data: 01.
2)
Set page: F, address: 29, data: 40 and press the PAUSE button
of the adjusting remote commander.
3)
Change the data of page: F, address: 39 and minimize “t1”,
and press the PAUSE button of the adjusting remote
commander. (Coarse adjustment)
4)
Change the data of page: F, address: 38, and adjust so that the
switching position (t1) becomes the specified value. (Fine
adjustment)
5)
Press the PAUSE button of the adjusting remote commander.
6)
Set page: F, address: 29, data: 00 and press the PAUSE button
of the adjusting remote commander.
7)
Set page: 0, address: 01, data: 00.
Fig. 5-3-8.
CH1
CH2
Enlargement
t1=0
±
10
µ
sec
CH1
CH2
3-4.
VIDEO SYSTEM ADJUSTMENTS
Video system adjustments must be performed in the following order.
[Adjusting Order]
1.
28 MHz origin oscillation adjustment
2.
Filter f0 adjustment
3.
Y OUT level adjustment
4.
C OUT level adjustment
5.
RP filter f0 adjustment
6.
AFC f0 adjustment
7.
NTSC Hi8 REC Y current adjustment
8.
PAL Hi8 REC Y current adjustment
9.
NTSC Hi8 REC C current adjustment
10. PAL Hi8 REC C current adjustment
11. REC C current adjustment
1. 28 MHz Origin Oscillation Adjustment (VC-197 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Note 1 :
If the x2 frequency is displayed, insert a 1 k
Ω
resistor
between the measuring point and probe.
Note 2 :
NTSC model : GV-A500
PAL model : GV-A500E
Mode
VTR stop
Subject
Arbitrary
Measurement Point
Pin
6
of IC206
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
3B
Specified Value
f = 14318181 ± 71 Hz (NTSC)
f = 14187500 ± 70 Hz (PAL)
Adjusting method:
1)
Set page: 0, address: 01, data: 01.
2)
Set page: 3, address: 01, data: 41 and press the PAUSE button
of the adjusting remote commander.
3)
Change the data of page: F, address: 3B, and set the oscillation
frequency (f) to the specified value.
4)
Press the PAUSE button of the adjusting remote commander.
5)
Set page: 3, address: 01, data: 00 and press the PAUSE button
of the adjusting remote commander.
6)
Set page: 0, address: 01, data: 00.
Содержание GV-A500E
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 10: ......
Страница 11: ......
Страница 12: ......
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ......
Страница 52: ......
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......