2-23
EVI-D100/EVI-D100P
13) Convert D
4
to decimal notation, and obtain D
4
’. (Refer
to page 2-7 “Hexadecimal notation - decimal notation
conversion table”.)
14) Calculate D
6
’ using the following equations. (Equa-
tions 3 and 4 are for decimal notation calculation).
When D
5
>
F0
D
6
’ = D
4
’
_
13
When D
5
< F0
D
6
’ = D
4
’
_
14
15) Convert D
6
’ to hexadecimal notation, and obtain D
6
.
16) Select page: F, address: 3D, set data: D
6
, and press the
PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: D, address: 11, and set data: 00, and press
the PAUSE button of the adjusting remote commander.
2) Select page: 2, address: 01, and set data: 00, and press
the PAUSE button of the adjusting remote commander.
3) Select page: 2, address: 40, and set data: 00.
4) Select page: 0, address: 03, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
10. IRIS IN/OUT Adjustment
For the unit to judge if the white balance is indoors or
outdoors in auto white balance operations, measure the
light level and write it in the EEPROM.
If the level is not correct, the white balance will not be
accurate.
Subject
Clear chart
(Color bar standard picture frame)
Measurement Point
DDS display of TV monitor (
*
)
Measuring Instrument
Adjustment Page
F
Adjustment Address
3C, 3D
n
*
: The right four digits of the display data at the right
bottom side of TV monitor is the LIGHT LEVEL data.
If the right two digits of the display data changes,
regard the data as data: 80.
00 XX XX
Lower two digits
Upper two digits
Adjusting method
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 03, and set data: 06.
3) Select page: D, address: 11, and set data: 02, and press
the PAUSE button of the adjusting remote commander.
4) Select page: 2, address: 40, and set data: 02.
5) Select page: 2, address: 01, set data: 0B, and press the
PAUSE button of the adjusting remote commander.
6) Read the DDS display data (
*
), and take the upper two
digits as D
1
and the lower two as D
2
.
7) Convert D
1
to decimal notation, and obtain D
1
’. (Refer
to page 2-7 “Hexadecimal notation - decimal notation
conversion table”.)
8) Calculate D
3
’ using the following equations. (Equa-
tions 1 and 2 are for decimal notation calculation).
When D
2
>
D0
D
3
’ = D
1
’
_
21
When D
2
< D0
D
3
’ = D
1
’
_
22
9) Convert D
3
’ to hexadecimal notation, and obtain D
3
.
10) Select page: F, address: 3C, set data: D
3
, and press the
PAUSE button of the adjusting remote commander.
11) Select page: 2, address: 01, set data: 09, and press the
PAUSE button of the adjusting remote commander.
12) Read the DDS display data (
*
), and take the upper two
digits as D
4
and the lower two as D
5
.
..................................... Equation 1
..................................... Equation 2
..................................... Equation 3
..................................... Equation 4