3-11
DXC-D30WS/P(E)/V1
3-3-14. Flare Adjustment
Object:
Grayscale chart
Equipment:
Waveform monitor
Preparation:
OUTPUT/DL/DCC
+
switch/camera side
→
CAM/DCC
+
Adjustment Procedure
1. SERVICE menu “PAGE 3”
→
R FLARE: x
G FLARE: 0
B FLARE: x
Note:
Make sure that “G FLARE” must be “0”.
2. Chart frame = Underscanned monitor frame
3. Test point:
VIDEO OUT connector/camera side
Adjusting point: Lens iris
Specification:
A = 100
±
2 IRE (for NTSC)
700
±
10 mV (for PAL)
3-3-15. MIC LEVEL/MIC Level IND Adjustment
Equipment:
Oscilloscope
Preparation:
OUTPUT/DL/DCC
+
switch/camera side
→
BARS
Adjustment Procedure
1. Test point:
CL201/MB-785 board
(GND: Capacitor, C202
+
side/MB-785
board)
Adjusting point:
1
RV201/MB-785 board
110 ± 5 mV
4. Open the lens iris by two steps.
5. Adjust “R FLARE” and “B FLARE” alternately by UP
4
witch or DOWN
$
witch so that the carrier leakage
level is minimum.
2. SERVICE menu “PAGE 17”
→
MIC ADJ :
3. Adjust the DOWN
$
switch, and stop where the
mark just appears on the monitor screen.
4. Adjust the UP
4
switch, and step where the mark just
disappears on the monitor screen.
5. And, set the mark to the value that subtract 10 time
from the value by DOWN
$
switch where the mark
just disappears.
Monitor screen or Viewfinder screen.