5-53
DSR-45/45P
3-3. SERVO AND RF SYSTEM ADJUSTMENTS
1.
Capstan FG Adjustment (CM-59 Board)
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
E-E
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
16
Specified Value
“ 00 ”
Adjusting method:
1) Close the cassette compartment without tape.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: 3, address: 01, set data: 1B, and press the PAUSE
button of adjustment remote commander.
4) Select page: 3, address: 02 , and check that the data change to
“ 1B ”
→
“ 2B ”
→
“ 00 ”.
5) Select page: 3, address: 03, and check data: “ 00 ”.
Note:
If page: 3, address: 03 is “ 01 ”, there are errors.
6) Set page: 0, address: 01, and set data: 00.
2.
PLL f
0
Pre-adjustment (RP-234 Board)
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
E-E
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 47
Specified Value
“ 00 ”
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 30, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 3, address: 02, and check that the data changes to
“ 00 ”.
4) Select page: 3, address: 03, and check that the data is “ 00 ”.
5) Select page: 0, address: 01, and set data: 00.
3.
Switching Position Adjustment (RP-234 Board)
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
Playback
Signal
Alignment tape: SW/OL standard
(XH2-3)
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified Value
“ 00 ”
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 3, address: 02, and check that the data changes to
“ 00 ”.
4) Select page: 3, address: 03, and check that the data is “ 00 ”.
5) Select page: 0, address: 01, and set data: 00.
4.
RF-AGC Adjustment (RP-234 Board)
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
Recording and playback
Signal
Color bar
Measurement Point
Displayed data of page: 3, address:
03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1E
Specified Value
“ 00 ”
Adjusting method:
1) Record the color bar signal in the optional tape about 2 min-
utes.
2) Select page: 0, address: 01, and set data: 01.
3) Select page: C, address: 54, set data: CC, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 3, address: 1D, set data: 21, and press the PAUSE
button.
5) Play back the recorded section.
6) Select page: 3, address: 01, set data: 23, and press the PAUSE
button.
7) Select page: 3, address: 02, and check that the data changes to
“ 00 ”.
8) Select page: 3, address: 03, and check that the data is “ 00 ”.
9) Select page: 3, address: 1D, set data: 20, and press the PAUSE
button.
10) Select page: C, address: 54, set data: 00, and press the PAUSE
button.
11) Select page: 0, address: 01, and set data: 00.
Содержание DVCAM DSR-45P
Страница 112: ...DSR 45 45P 2 1 4 117 4 118 RP 234 ...
Страница 116: ...DSR 45 45P 12 4 125 4 126 DI 73 ...
Страница 120: ...DSR 45 45P 4 133 4 134 CM 59 49 48 33 32 17 16 1 2 22 ...
Страница 127: ...DSR 45 45P 4 147 4 148 JK 216 JK 216 VIDEO AUDIO IN OUT ...
Страница 138: ...4 166 DSR 45 45P el 32 768 MHz IC6001 ts REC PB 2 3 Vp p r 20 MHz IC6001 ra REC PB 1 6 Vp p JC 21 BOARD 5 5 ...
Страница 150: ...4 178 DSR 45 45P PD 170 BOARD 2 2 qa IC901 ej REC PB 2 8 Vp p H ...
Страница 304: ... 404 Sony EMCS Co 9 929 941 11 2002D0500 1 2002 4 Published by DI Customer Center DSR 45 45P ...
Страница 305: ...Revision History Reverse Ver 1 0 Date 2002 04 History Official Release Contents S M Rev issued 992994111 pdf ...