5-66
3-4.
SERVO SYSTEM ADJUSTMENTS
1.
Switching Position Adjustment (CM-56 Board)
Mode
Playback
signal
SW/OL reference tape
Measurement Point
Page: 3, address: 03 on displayed data of
adjusting remote commander
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
4C, 4D, 4E, 4F
Specified Value
“00”
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 0E, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 3, address: 02, and confirm that the data changes
from “0E” to “00”.
4) Select page: 3, address: 03, and confirm that the data is “00”.
5) Turn OFF the HOLD switch on he adjusting remote commander
and wait for more than 2 seconds. (The adjusted data are auto-
matically written to page: C, address: 4C to 4F)
6) Turn ON the HOLD switch on the adjusting remote com-
mander.
7) Select page: 0, address: 01, and set data: 00.
8) Stop the tape playback.
9) Turn the POWER switch OFF.
2.
Capstan FG Duty Adjustment (CM-56 Board)
Mode
Playback
signal
Arbitrary tape
Measurement Point
Page: 3, address: 03 on displayed data of
adjusting remote commander
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
50, 51
Specified Value
“00”
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 15, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 3, address: 02, and confirm that the data changes
from “15” to “00”.
4) Select page: 3, address: 03, and confirm that the data is the
following value
When “00”: Normal
When “01”: Faulty
Perform the following adjustment only when “00” is displayed.
5) Select page: 3, address: 04 and 05, read the data, and take the
values as D
04
and D
05
respectively.
(The data on page: 3, address: 05 must be 2F to 3F)
6) Select page: C, address: 50, set data: D
04
, and press the PAUSE
button of the adjusting remote commander.
7) Select page: C, address: 51, set data: D
05
, and press the PAUSE
button of the adjusting remote commander.
8) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
9) Select page: 0, address: 01, and set data: 00.
10) Stop the tape playback.
11) Turn the POWER switch OFF.
Содержание DSR-20MD
Страница 8: ...1 1 SECTION 1 GENERAL This section is extracted from DSR 20MD 20MDP instruction manual DSR 20MD 20MDP ...
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 1 10 E ...
Страница 131: ...5 39 5 34 LID OPENER Removing Attaching 1 2 3 5 4 Lid opener C slider R Bend with holding here Lid opener ...
Страница 223: ... 294 DSR 20MD 20MDP 9 974 189 11 Sony EMCS Co 2007E0500 1 2007 5 Published by Kohda TEC ...