5-52
6-3-9.
CUE AND REV CHECK
XH2-1
POWER
CH1
EXT
TRIG
Trigger slope: +
Oscilloscope
DECK
RP board
1
Connection.
Refer to
2
Connection of
6-3-6. Adjustment
preparations.
2
Playback.
Tracking tape
(XH2-1 AST)
Note: Tape Path (Refer
to page 5-4) (J-5)
Waveform in CUE or REV.
OK: The distance between peaks should be equal.
NG: The distance between peaks is not equal.
3
Check the waveform in the
M
mode.
CUE
(see the left figure)
4
Check the waveform in the
m
mode.
REV
(see the left figure)
If
3
or
4
is “NG”, perform “6-3-7. TRACKING
ADJUSTMENT” again.
Содержание DSR-20MD
Страница 8: ...1 1 SECTION 1 GENERAL This section is extracted from DSR 20MD 20MDP instruction manual DSR 20MD 20MDP ...
Страница 9: ...1 2 ...
Страница 10: ...1 3 ...
Страница 11: ...1 4 ...
Страница 12: ...1 5 ...
Страница 13: ...1 6 ...
Страница 14: ...1 7 ...
Страница 15: ...1 8 ...
Страница 16: ...1 9 ...
Страница 17: ...1 10 1 10 E ...
Страница 131: ...5 39 5 34 LID OPENER Removing Attaching 1 2 3 5 4 Lid opener C slider R Bend with holding here Lid opener ...
Страница 223: ... 294 DSR 20MD 20MDP 9 974 189 11 Sony EMCS Co 2007E0500 1 2007 5 Published by Kohda TEC ...