![Sony DP-IF5100 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/sony/dp-if5100/dp-if5100_service-manual_400236008.webp)
– 8 –
SECTION 4
ELECTRICAL ADJUSTMENTS
Notes:
1. These adjustments are performed in the order that they are
described.
2. Adjustment and measurement are performed for each channel
unless otherwise specified.
3. Adjustment is made for the right channel first and then the left
channel.
4. The power voltage is supplied with 9 V.
Oscillation Frequency Adjustment
Setting:
+
–
LED board
TP03 or TP04 (L-ch)
TP05 or TP06 (R-ch)
digital frequency
counter
Adjustment method:
• Perform this adjustment without signal.
1. Connect TP (A MUTE) to ground on the TX board (to set the
mute state), or use the test mode to set the mute state (see page
7).
2. Connect a digital frequency counter to TP03 or TP04 for L-ch
and TP05 or TP06 for R-ch on the LED board.
3. Adjust L51 (L-ch) and L1 (R-ch) on the TX board so that the
reading on the digital frequency counter is each within 2.3 MHz
(L-ch) and 2.8 MHz (R-ch).
Specified value:
L-ch
L51
2.298 to 2.302 MHz
R-ch
L1
2.798 to 2.802 MHz
RF Level Adjustment
Setting:
digital voltmeter
+
–
LED board
TP03 or TP04 (L-ch)
TP05 or TP06 (R-ch)
board (to set the mute state), or use the test mode to set the mute
state (see page 7).
2. Connect a digital voltmeter to TP03 or TP04 for L-ch and TP05
or TP06 for R-ch on the LED board.
3. Adjust RV51 (L-ch) and RV1 (R-ch) on the TX board so that
the reading on the digital voltmeter is 480 mV.
Specified value:
L-ch
RV51
477.5 to 482.5 mV
R-ch
RV1
477.5 to 482.5 mV
Adjustment Location:
RV51
RF LEVEL
ADJUSTMENT
OSCILLATION
FREQUENCY
ADJUSTMENT
L51
RV1
L1
– TX board (side A) –
TP05
TP06
TP03
TP04
– LED board (conductor side) –
– TX board (side A) –
TP
(A MUTE)