Chapter 4 Adjustments and Settings for Recording
4-33
4
Example 2: Interconnecting a number of camcorders for time code
synchronization
Camcorder to be synchronized
Camcorder to be synchronized
Reference camcorder
VIDEO OUT or TEST OUT
2)
TC OUT
TC IN
GENLOCK IN
1)
TC OUT
VIDEO OUT or TEST OUT
2)
GENLOCK IN
1)
TC IN
TC OUT
VIDEO OUT or TEST OUT
2)
To another camcorder to be
synchronized
....................................................................................................................................
1) Set GENLOCK to ON from the FUNCTION 2/2 page of the setup menu.
For information about this setting, see Section 4-9-2 “Selecting the Functions”
(page 4-79).
2) Output a composite video signal from the TEST OUT connector. In the
FUNCTION 1/2 page of the setup menu, set TEST OUT to ENC.
For more information, see Section 4-9-3 “Selecting the Test Output” (page 4-
83).