5-51
DCR-PC115/PC115E/PC120BT/PC120E
3-3.
SERVO AND RF SYSTEM ADJUSTMENT
Before perform the servo and RF system adjustments, check that
the specified value of “40.5MHz/54MHz Origin Oscillation
Adjustment” of “CAMERA SYSTEM ADJUSTMENT” is satisfied.
Adjusting Procedure:
1.
Cap FG duty adjustment
2.
PLL f
0
& LPF f
0
adjustment
3.
Switching position adjustment`
4.
AGC center level
5.
APC & AEQ adjustment
6.
PLL f
0
& LPF f
0
fine adjustment
1. Cap FG Duty Adjustment (VC-270 board)
Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
16
Specified Value
00
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting a cassette.
2
0
01
01
Set the data.
3
3
01
1B
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes in
the following order.
“1B”
→
“2B”
→
“00”
5
3
03
Check that the data is “00”.
(Note)
6
0
01
00
Set the data.
Note:
If the data is “01”, adjustment has errors or the mechanism deck is
defective.
2. PLL f
0
& LPF f
0
Adjustment (VC-270 board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 02,
03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
21
CA
Set the data, and press PAUSE
button.
3
3
01
00
Set the data, and press PAUSE
button.
4
3
01
30
Set the data, and press PAUSE
button.
5
3
02
Check that the data changes to
“00” with in 5 sec. (Note)
6
3
03
Check that the data is “00”.
(Note)
7
0
01
00
Set the data.
Note:
If it isn’t satisfied, select page: C, address: 21, set the following
data, and press the PAUSE button, and repeat steps 3 to 6.
Setting data
When the data of page: C, address: 21 is “CA”.
CE
When the data of page: C, address: 21 is “CE”.
C6
When the data of page: C, address: 21 is “C6”.
D2
When the data of page: C, address: 21 is “D2”
C2
There are errors when it isn’t satisfied even if the above treatment is
done.
If bit2, bit3, bit4, bit5 or bit 6 of the data of page: 3, address: 03 is
“1”, there are errors. For the error contents, see the following table.
(For the bit values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.)
Bit value of page: 3,
Error contents
address: 03 data
bit 2 = 1 or bit 3 = 1
PLL f
0
fine adjustment is defective
bit 4 = 1 or bit 5 = 1
PLL f
0
adjustment is defective
bit 6 = 1
LPF f
0
adjustment is defective
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
Содержание DCR-PC115
Страница 102: ...DCR PC115 PC115E PC120BT PC120E 4 13 4 14 CCD IMAGER CD 349 Uses unleaded solder ...
Страница 110: ...DCR PC115 PC115E PC120BT PC120E 4 69 4 70 RGB DRIVE TIMING GENERATOR MIC AMP VM 027 Uses unleaded solder ...
Страница 124: ...5 1 DCR PC115 PC115E PC120BT PC120E SECTION 5 ADJUSTMENTS ...
Страница 207: ...Revision History Ver 1 0 Date 2001 09 History Official Release Contents S M Rev issued 992992131 pdf Reverse ...