5-25
DCR-PC115/PC115E/PC120BT/PC120E
7. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
7-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 350 ± 30 lux)
Measurement Point
Display data of page: F, address: 59
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
40 to 45, 50 to 59
Specified Value
00 to 0E
Note 1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note 2:
This adjustment should be carried out upon completion of the
following adjustments.
HALL adjustment
MR adjustment
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE button.
3
6
01
15
Set the data, and press PAUSE button.
4
6
02
Check that the data changes to
“01”. (Note 3)
5
F
59
Check that the data is “00” to “0E”.
Note 3:
The adjustment data will be automatically input to page: F, address:
40 to 45, 50 to 59.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE button.
2
Perform “Flange Back
Adjustment (2)”
7-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
40 to 45, 50 to 59
Note 1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE button.
Place a ND filter on the lens so
that the optimum image is
obtain.
3
6
01
29
Set the data, and press PAUSE button.
4
6
02
Check that the data changes to
“01”. (Note 2)
Note 2:
The adjustment data will be automatically input to page: F, address:
40 to 45, 50 to 59.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE button.
2
0
01
00
Set the data.
3
Perform “Flange Back Check”.
RadarW
RadarW
RadarW
Содержание DCR-PC115
Страница 102: ...DCR PC115 PC115E PC120BT PC120E 4 13 4 14 CCD IMAGER CD 349 Uses unleaded solder ...
Страница 110: ...DCR PC115 PC115E PC120BT PC120E 4 69 4 70 RGB DRIVE TIMING GENERATOR MIC AMP VM 027 Uses unleaded solder ...
Страница 124: ...5 1 DCR PC115 PC115E PC120BT PC120E SECTION 5 ADJUSTMENTS ...
Страница 207: ...Revision History Ver 1 0 Date 2001 09 History Official Release Contents S M Rev issued 992992131 pdf Reverse ...