6-27
DCR-HC39E/HC41/HC42/HC42E/HC43/HC43E
5-2.
Flange Back Adjustment (2)
RadarW
RadarW
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
11, 48 to 58
Specified value
Data of page: F, address: 57 is“00” to “0B”
Data of page: 6, address: 0C is“00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 4:
Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
13
Press PAUSE button.
3
Wait for 2 seconds.
4
Place ND filter on the lens so
that the optimum image is
obtain.
5
6
01
29
Press PAUSE button. (Note 5)
6
6
02
Check the data changes to “01”.
7
6
0C
Check the data is “00”.
8
F
57
Check the data is “00” to “0B”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 11, 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
0
01
00
5
Perform “Flange Back
Check”.
6.
Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Note 2:
When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
Shoot the Siemens star with
the zoom TELE end.
4
Turn on the auto focus.
5
0
03
0F
6
1
Check that the lens is
focused. (Note 2)
7
6
21
10
8
Shoot the Siemens star with
the zoom WIDE end.
9
Observe the TV monitor and
check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
0
03
00
Содержание DCR-HC41
Страница 3: ... 3 DCR HC39E HC41 HC42 HC42E HC43 HC43E ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 6: ... 6 DCR HC39E HC41 HC42 HC42E HC43 HC43E ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 12: ...1 5 DCR HC39E HC41 HC42 HC42E HC43 HC43E ENGLISH JAPANESE ENGLISH JAPANESE 1 SERVICE NOTE ...
Страница 13: ...1 6 DCR HC39E HC41 HC42 HC42E HC43 HC43E ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 14: ...1 7 DCR HC39E HC41 HC42 HC42E HC43 HC43E ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 15: ...1 8E DCR HC39E HC41 HC42 HC42E HC43 HC43E ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 76: ...5 24E DCR HC39E HC41 HC42 HC42E HC43 HC43E J MODEL ...
Страница 78: ...ENGLISH JAPANESE ENGLISH JAPANESE ...
Страница 159: ... 7 DV MECHANICAL ADJUSTMENT MANUAL VII J 1 J 2 J 3 J 4 J 5 J 6 J 7 J 8 J 9 J 10 J 11 J 12 J 13 Fig 2 2 ...
Страница 215: ...DV MECHANICAL ADJUSTMENT MANUAL VII 60 Sony EMCS Co 2003A1600 1 2003 1 Published by DI Customer Center 9 876 210 11 ...
Страница 216: ...Revision History 987621011 pdf Reverse Ver 1 0 Date 2003 01 History Official Release Contents S M Rev issued ...