5-3
5-1. CAMERA SECTION ADJUSTMENT
1-1.
PREPARATIONS BEFORE ADJUSTMENT
1-1-1. List of Service Tools
• Oscilloscope
• Color monitor
• Vectorscope
• Regulated power supply
• Digital voltmeter
Note 1:
If the micro processor IC in the adjustment remote
commander is not the new micro processor (UPD7503G-
C56-12), The pages cannot be switched. In this case,
replace with the new micro processor (8-759-148-35).
Note 2:
The old CPC-9 jig (Parts code: J-6082-393-B) cannot be
used, because it cannot operate the adjustment remote
commander.
J-1
J-5
J-2
J-6
J-7
J-3
J-4
Fig. 5-1-1
J-8
J-9
J-10
J-11
Ref. No.
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
J-9
J-10
J-11
Name
Filter for color temperature correction (C14)
Pattern box PTB-450
Color chart for pattern box
Adjustment remote commander (RM-95 upgraded).
(Note 1)
Siemens star chart
Clear chart for pattern box
CPC-9 jig (Note 2)
Mini pattern box
Extension cable (16P, 0.5mm, L=200mm)
Extension cable (16P, 0.5mm, L=100mm)
Extension cable (18P, 0.5mm)
Back ground paper
Parts Code
J-6080-058-A
J-6082-200-A
J-6020-250-A
J-6082-053-B
J-6080-875-A
J-6080-621-A
J-6082-393-C
J-6082-353-B
J-6082-398-A
J-6082-357-A
J-6082-423-A
J-2501-130-A
Usage
Auto white balance adjustment/check
White balance adjustment/check
For checking the flange back
For connecting the adjustment remote commander
For adjusting the LCD block
For adjusting the flange back
For extension between the DD-141 board (CN851) and
the SL-56 board (CN251)
For extension between the CD-282 board (CN401) and
the SY-58 board (CN101)
For adjusting the strobe