DSC-P9
5-20
8.
Auto White Balance 3200K Standard Data Input 1
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end and
TELE end)
Adjustment Page
F
Adjustment Address
70 to 77, B0, B2, B4
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 1” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (WIDE end)
(Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
7
5D
Note down the data.
6
7
5D
00
Press PAUSE button.
7
7
9D
Note down the data.
8
7
9D
80
Press PAUSE button.
9
6
37
01
10
6
01
11
Press PAUSE button.
11
6
38
Check the data changes to
“01”.
12
6
01
C1
Press PAUSE button. (Note 3)
13
6
02
Check the data changes to
“01”.
14
7
5D
Set data noted down at step 5,
and press PAUSE button.
15
7
9D
Set data noted down at step 7,
and press PAUSE button.
16
6
01
00
Press PAUSE button.
17
Perform “Picture Frame
setting”. (TELE end)
(Refer to page 5-15)
18
6
37
02
19
6
01
0B
Press PAUSE button. (Note 3)
20
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 70 to 77, B0, B2 and B4.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
Set data noted down at step 3,
and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 5-14)