6-22
DSC-P72
11. Auto White Balance 5800K Check
Check that the white balance standard data at 5800K are inputted
properly.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Data of page: 10, address: 08, 09, 0A,
0B, 59, 5B
Measuring Instrument
Data of page: 6F, address: 8C, 8E, B5
Specified value 1
R ratio = 2838 to 2C38
Specified value 2
B ratio = 5DA0 to 61A0
Specified value 3
R-Y data = 70 to 90
Specified value 4
B-Y data = 70 to 90
Specified value 5
R/G data = 10 to 40
Specified value 6
B/G data = 10 to 40
Specified value 7
00
Note1:
Before perform this adjustment, perform “Auto White Balance
5800K Standard Data Input”.
Note2:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
Check that “1. Data Setting during
Camera System Adjustments” is
performed.
3
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
4
00
01
01
Set the data.
5
6F
B5
FF
Write the data.
5800K standard data Check (1).
6
60
37
13
Write the data.
7
60
01
11
Write the data.
8
60
38
Read the data, and check it is “01”.
9
60
01
C3
Write the data.
10
Wait for 2 sec.
11
60
02
Read the data, and check it is “01”.
12
10
08
Read the data, and this data is
named D
08
.
13
10
09
Read the data, and this data is
named D
09
.
14
Calculate R ratio using the
following equation.
(Hexadecimal calculation.)
R ratio = D
08
×
100 + D
09
15
Check that R ratio satisfies the
specified value1.
16
10
0A
Read the data, and this data is
named D
0A
.
Order Page Address Data
Procedure
17
10
0B
Read the data, and this data is
named D
0B
.
18
Calculate B ratio using the
following equation.
(Hexadecimal calculation.)
B ratio = D
0A
×
100 + D
0B
19
Check that B ratio satisfies the
specified value 2.
20
10
59
Read the data (R-Y data), and
check it satisfies the specified
value 3.
21
10
5B
Read the data (B-Y data), and
check it satisfies the specified
value 4.
22
60
01
00
Write the data.
5800K standard data Check (2).
23
6F
8C
Read the data (R/G data), and
check it satisfies the specified
value 5.
24
6F
8E
Read the data (B/G data), and
check it satisfies the specified
value 6.
25
6F
B5
Read the data, and check it
satisfies the specified value 7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
37
00
Write the data.
2
60
01
00
Write the data.
3
Perform next adjustments.
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
Содержание Cyber-Shot DSC-P72
Страница 1: ...http servis manual com ...