6-18
DSC-P72
5. F No. Standard Data Input
Adjusted the dispersion of the iris to every to every F number, and
compensate the exposure.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 6F, address: 6B
Measuring Instrument
Adjustment Page
6F
Adjustment Address
60 to 64, 6B to 6D
Specified value
00
Note1:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
3
00
01
01
Set the data.
4
60
01
BB
Write the data.
5
Wait for 1 sec.
6
60
02
Red the data, and check it is “01”.
(Note2)
7
6F
6B
Read the data, and check it
satisfies the specified value.
Note2:
The adjustment data will be automatically input to page: 6F,
address: 60 to 64, 6B to 6D.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)
6. Mechanical Shutter Adjustment
Adjust the dispersion of the opening/closing time and the closing
loss rate of the mechanical shutter. and compensate the exposure.
Mode
STILL (
)
Subject
Clear chart
(Standard picture frame)
Measurement Point
Data of page: 6F, address: 6B
Measuring Instrument
Adjustment Page
6F
Adjustment Address
6B to 6D, B8 to D7
Specified value
00
Note1:
If the data of page: 60, address: 02 is “01”, select page: 60, address:
01, and write data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
CAMERA setting (Menu setting) ................................ AUTO
Adjusting method:
Order Page Address Data
Procedure
1
Check that “1. Data Setting
during Camera System
Adjustments” is performed.
2
Check the picture frame.
If deviated, perform “4. Picture
Frame Setting”.
3
00
01
01
Set the data.
4
60
01
AD
Write the data.
5
Wait until the movement of the
shutter stops.
6
60
02
Read the data, and check it is “01”.
(Note2)
7
6F
6B
Read the data, and check it
satisfies the specified value.
Note2:
The adjustment data will be automatically input to page: 6F,
address: 6B to 6D, B8 to D7.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
60
01
00
Write the data.
2
If finish the camera system
adjustments, release the data
setting.
(See “1. Data Setting during
Camera System Adjustments”.)